E-12
6
Wiring
When the FG terminal is connected, be sure the wire is grounded.
Not grounding the PS-G unit will result in excess noise and vibra-
tion.
• Wherever possible, use thick wires (max. 2 mm
2
) for PS-G power cord
power terminals. Also, to reduce noise be sure to twist the wire ends
before attaching the connectors.
• Use the following sized Ring Terminals.
Power Input
Terminal Block
Rear of AC100V PS-G Unit
N
L
FG
Ring Terminals*
1
Over
φφφφφ
3.2mm(0.13in)
Under 6.0mm(0.24in)
L N FG
• To avoid a short caused by loose ring terminals, be sure to use ring
terminals with an insulating sleeve.
• To avoid an electric shock, check that the PS-G's power supply is
completely turned OFF, via a breaker, or similar unit before con-
necting the PS-G's power cord terminals to the power terminal block.
• The PS600G-T11-J1can accept only AC100V input. If you use power
other than AC100V, you can damage both the power supply and
the PS-G unit.
• Since the PS-G unit has no power ON/OFF switch, be sure to
attach a breaker type switch to its power cord.
WARNINGS
*1
L : AC Input Terminal-live line
N : AC Input Terminal-neutral line
FG : Ground Terminal connected to the PS-G chassis
Suggested Ring Terminal : V2-MS3 (made by JST)