E-10
5
Installation
• Before installing the PS-G into a cabinet or panel, check that the instal-
lation gasket is securely attached to the unit.
• A gasket which has been used for a long period of time may have
scratches or dirt on it, and could have lost much of its water resistance.
Be sure to change the gasket at least once a year, or when scratches
or dirt become visible.
• Be sure to use gasket model GP570-WP10-MS.
• Be sure the gasket's seam is not inserted into any of the unit's corners,
only in the straight sections of the groove. Inserting it into a corner may
lead to its eventually tearing.
Confirm the Installation Gasket's Positioning
Unit: mm [in.]
Create a Panel Cut
Insert the PS-G into the panel from the front
Attach the Installation Fasteners from Inside the Panel
The following figures show the four (4) insertion slot locations of the PS-G
installation fasteners. Insert the hook section into the slot and tighten the
fastener with a screwdriver, as shown.
Insertion Slots
Insertion Slots
Top
Bottom
It is strongly recommended that you use the installation gasket.
Place the PS-G on a level surface with the display panel facing downward.
Check that the PS-G’s installation gasket is seated securely into the gasket’s
groove, which runs around the perimeter of the panel’s frame.
Panel
Panel thickness
1.6mm[0.06in] to
10mm[0.39in]
Gasket
Rear of PS-G unit
PS
301.5
[11.87 ]
+1
0
under 4-R3
PS
Panel
+0.04
0
227.5
+1
0
+0.04
0
[8
.96
]