background image

7

Grounding Cautions

• Be sure to create an exclusive ground for 

the Power Cord’s FG terminal. Use a 

grounding resistance of 100 

, a wire of 

2mm

2

 or thicker, or ground using your 

country’s applicable standard.

• The SG (signal ground) and FG (frame 

ground) terminals are connected internally 

in the GP3000H.

When connecting the SG line to another 

device, be sure that the design of the 

system/connection does not produce a 

ground loop.

• The grounding wire should have a 

diameter greater than 2 mm

2

. Create the 

connection point as close to the GP3000H 

as possible, and make the wire as short as 

possible. When using a long grounding 

wire, replace the thin wire with a thicker 

wire, and place it in a duct.

Input/Output Signal Line Cautions

• All GP3000H Input and Output signal 

lines must be separated from all operating 

circuit (power) cables.

• If the operating circuit (power) cables 

cannot be separated, use a shielded cable 

and ground the shield.

GP3000H

Other

Equipment

Exclusive Grounding

(BEST)

GP3000H

Other

Equipment

Common Grounding (OK)

GP3000H

Other

Equipment

Common Grounding

(Not OK)

Содержание GP3000H

Страница 1: ...es or medical life support equipment due to these devices inherent requirements of extremely high levels of safety and reliability When using this cable with transportation vehicles trains cars and ships disaster and crime prevention devices various types of safety equipment non life support related medical devices etc use redundant and or failsafe system designs to ensure reliability and safety P...

Страница 2: ...C Conversion Adapter GP2000H AP232 GP2000H RS 422 Conversion Adapter GP2000H AP422 Mitsubishi PLC A QnA FX Series 2 Port Adapter II GP070 MD11 DC24V RS 232C Cable GP410 IS00 O 1 This cable GP3000H CBLSD232 3M GP3000H CBLSD232 10M GP3000H DC24V RS 232C Cable Prepared by user Host Controller PLC etc Host Controller PLC etc RS 422 Cable Prepared by user This cable GP3000H CBLSD422 3M GP3000H CBLSD422...

Страница 3: ...ning torque of 0 5N m Avoid bending this cable excessively and pulling this cable with excessive force Excessive bending and pulling can result in cable disconnection Name Model Description GP3000H Soft type 3 m Cable for GP2000H Conversion Adapter RS 232C with connector GP3000H CBLSD232 3M The cable between the GP2000H Series RS 232C Conversion Adapter and the GP3000H equipped with D Sub connecto...

Страница 4: ...3 Turn the cable connector lock ring to lock the connector so that the small mark for LOCK on the lock ring is aligned with the small mark on the cable connector Removal 1 Unlock the connector that has been locked in the mounting procedure Turn the lock ring as shown so that the small mark is displaced from the mark Then pull out the cable by holding the cable connector To disconnect the cable be ...

Страница 5: ... RESERVE Not labeled 5 OP C OP 6 OP GND OPG 7 BUZZ OUT BZ 8 DOUT GND DOG 9 EMG0A EM0A Emergency switch 0A Normally Open 2 2 To improve noise resistance be sure to twist each pair of wires close to the terminal block 10 EMG0B EM0B Emergency switch 0B Normally Open 2 11 EMG1A EM1A Emergency switch 1A Normally Closed 2 12 EMG1B EM1B Emergency switch 1B Normally Closed 2 13 EMG2A EM2A Emergency switch...

Страница 6: ... s power supply cord should not be bundled with or kept close to main circuit lines high voltage high current or input output signal lines To improve noise resistance make the power cord as short as possible If the supplied voltage exceeds the GP3000H s range connect a voltage transformer Between the line and the ground be sure to use a low noise power supply If there is an excess amount of noise ...

Страница 7: ...nding wire should have a diameter greater than 2 mm2 Create the connection point as close to the GP3000H as possible and make the wire as short as possible When using a long grounding wire replace the thin wire with a thicker wire and place it in a duct Input Output Signal Line Cautions All GP3000H Input and Output signal lines must be separated from all operating circuit power cables If the opera...

Страница 8: ...oofing standards Pro face s GP3000H Conversion Adapter model AGP3000H ADPCOM 01 and a dedicated cable sold separately are necessary to overcome these restrictions Please refer to Accessories in Chapter 1 Overview in the GP3000H Series Hardware Manual UL c UL Approval The system constructing the following three components does not conform to UL c UL standards GP3000H This cable GP2000H RS 232C RS 4...