background image

- 3 -

When attaching this adapter to a DIN rail, be sure to fix the cable in place so
that the cable connected is supported and does not place a weight load on the
connector. If the cable’s weight is not supported, it may eventually damage the
adapter or the DIN rail.

<Recommended Installation Method>

Be sure to install the Conversion adapter from inside the panel.

Use stud bolts 14mm [0.55in.] or longer, and secure them in place using M3 nuts. The
necessary torque is 0.5 to 0.6 N•m. The drawing shown here is with the recommended
connector and cover in place.

The size and depth of the attachment screw installation holes will vary depending on
the type of Dsub 37 pin connector used and the thickness of the panel.

„

Attaching the Adapter on a 35mm DIN Rail

• Attachment

Place the unit's curved, top lip over the top
of the DIN rail, and then tilt the unit down
until the bottom face attachment clip clicks
into place.

• Removal

Use a standard screwdriver to force
the unit's attachment clip down until
the bottom of the adapter is freed
from the rail. Next, tilt the adapter
up and remove.

Adapter

DIN Rail

Standard Screwdriver

Down

DIN Rail

Adapter

88±0.2[3.46±0.01]

under 4-R3

38.5±

0.2[1.52

±

0.01]

4-M3 Stud Bolt

L = 14mm [0.55in.] or longer

Use enough force when
attaching the bolts to cause
the rear of the panel to
protrude slightly.

Unit:mm[in.]

40.5     [1.59      ]

+1

 0

+0.04

 0

74      [2.91      ]

+1
 0

+0.04
 0

Содержание GP2000H Series

Страница 1: ...y built into your product When applying for UL approval for a product that includes one of this Adapter please be sure to pay special attention to the fact that all products with built in Adapter requ...

Страница 2: ...C Use the separately sold RS 232C cable GP410 IS00 O to connect the two 22 Line Terminal Block Connect external output DOUT etc or power lines to these terminals The lines cable connected here must be...

Страница 3: ...chment screw installation holes will vary depending on the type of Dsub 37 pin connector used and the thickness of the panel Attaching the Adapter on a 35mm DIN Rail Attachment Place the unit s curved...

Страница 4: ...ched The JST company s V2 MS3 round type Ring terminals or similar types are recommended To avoid a short caused by loose ring terminals be sure to use ring terminals with insulating sleeve The necess...

Страница 5: ...Ground 3 14 EMG0B Push Lock Switch 0B Operates like A contact 15 EMG1B Push Lock Switch 1B B contact 16 EMG2B Push Lock Switch 2B B contact 17 ENB0B Enable Switch 0B A contact 18 ENB1B Enable Switch 1...

Страница 6: ...ignal Ground 8 CD Carrier Detect 14 5V DC 5V 5 Output 0 25A 1 20 ER Enable to Receive 1 When connected to the GP the power used should be a maximum of 0 25A Be sure to not exceed this level Recommende...

Страница 7: ...n No Signal Name Drawing Name Description 1 DOUT0 C DO0 DOUT 0 Output 2 RESERVE Reserved 1 3 DOUT1 C DO1 DOUT 1 Output 4 RESERVE Reserved 1 5 OP C OP OP Output 6 OP GND OPG OP Ground 7 BUZZ OUT BZ Ext...

Страница 8: ...Note Please be aware that Digital Electronics Corporation shall not be held liable by the user for any damages losses or third party claims arising from the uses of this product Digital Electronics C...

Отзывы: