background image

22

   E

ngl

is

h

Installation

Installing to panel cutout for Monochrome Model
(GP-410*)

Step

Action

1

Place this product on a clean and level surface with the screen 
facing down.

2

Remove the gasket from this product.

3

Attach the panel cutout adapter (model number: PFXZCFAD31) 
to this product.
Check that the panel cutout adapter is seated securely into the 
bezel’s groove, which runs around the perimeter of the display 
panel frame.

1 Panel cutout adapter

NOTE :   

Always use the panel cutout adapter, since it absorbs vibration in 

addition to repelling water.

Содержание GP-4114T

Страница 1: ...GP 4100 Series Color Model Installation Guide...

Страница 2: ...fications Electrical Specifications 10 Environmental Specifications 10 Interface Interface Caution 11 Serial Interface 11 Installation Panel Cutout Dimensions 15 Installation Requirements 16 Installat...

Страница 3: ...4 English RTC Battery Set Overview 34 Attaching the RTC Battery Set 34 Replacing the Battery 36 Maintenance Cleaning this product 37 Standards Standards 38...

Страница 4: ...k at the equipment to become familiar with the device before trying to install operate or maintain it The following special messages may appear throughout this documentation or on the equipment to war...

Страница 5: ...equences arising out of the use of this material A qualified person is one who has skills and knowledge related to the construction and operation of electrical equipment and its installation and has r...

Страница 6: ...as a universal model number For more information on product models and their matching global codes please refer to the following URL http www pro face com trans en manual 1003 html Series Model name...

Страница 7: ...stener 2 pieces set 6 USB Clamp Type A 1 port 1 7 GP 4100 Series Color Model Installation Guide this guide 1 8 Warning Caution Information 1 This product has been carefully packed with special attenti...

Страница 8: ...d Functions A Power Connector B USB Type A Interface C USB mini B Interface D RTC Battery Set Cover E Ethernet Interface F Serial Interface G DIP Switch see page 12 Only on RS 422 485 type Ethernet ty...

Страница 9: ...When power is supplied to USB devices 8 1 W or less 7 5 W or less 7 7 W or less In rush current 12 Vdc 20 A or less 24 Vdc 40 A or less Voltage endurance 1 000 Vac 20 mA for 1 minute between charging...

Страница 10: ...OCK AND FIRE When using the SG terminal to connect an external device to this product Verify that a short circuit loop is not created when you set up the system Connect the SG terminal to remote equip...

Страница 11: ...nserting two wires into one terminal connector the simple wire diameter is 0 08 to 0 5 mm2 AWG 28 to 22 and the stranded wire diameter is 0 08 to 0 75 mm2 AWG 28 to 20 2 If the conductor s stranded wi...

Страница 12: ...tep Action 1 Use a flat blade screwdriver Size 0 4 X 2 5 to loosen the terminal screws 2 Strip the communications cable and attach it to the terminal connector 1 Communication cable 2 COM I F Connecto...

Страница 13: ...14 English Interface NOTICE BROKEN ENCLOSURE Do not exert more than 0 196 N m 1 735 lb in of torque when tightening the screws Failure to follow these instructions can result in equipment damage...

Страница 14: ...nstalling to panel cutout for monochrome model GP 410 NOTE The panel cutout adapter model number PFXZCFAD31 is required for this type of installation W H X R 112 5 mm 4 43 in 77 5 mm 3 05 in 1 5 6 mm...

Страница 15: ...his product with its front panel facing outward NOTE IP65F is not part of the UL certification The necessary torque to fasten the screw of the enclosed installation fasteners is 0 35 N m 3 1 lb in Che...

Страница 16: ...enclosure the surrounding air temperature is the cabinet s or enclosure s internal temperature 1 Cabinet interior 2 Panel face Be sure that heat from surrounding equipment does not cause this product...

Страница 17: ...ncline more than 30 the ambient temperature must not exceed 40 C 104 F You may need to use forced air cooling fan A C to ensure the ambient operating temperature is 40 C or less 104 F or less For easi...

Страница 18: ...om both this product and the power supply Always use a properly rated voltage sensing device to confirm power is off Replace and secure all covers or elements of the system before applying power to th...

Страница 19: ...gasket refer to the GP 4100 Series Color Model Hardware Manual 3 Based on this product s panel cutout dimensions see page 15 open a mount hole on the panel and attach this product to the panel from t...

Страница 20: ...e fastener s screws Failure to follow these instructions can result in equipment damage CAUTION RISK OF INJURY Do not drop this product when you remove it from the panel Hold this product in place aft...

Страница 21: ...Remove the gasket from this product 3 Attach the panel cutout adapter model number PFXZCFAD31 to this product Check that the panel cutout adapter is seated securely into the bezel s groove which runs...

Страница 22: ...to avoid hitting the projections 1 Projections 5 Insert the installation fastener hooks into the insertion slots on this product In a clockwise direction tighten the installation fastener s screws wit...

Страница 23: ...English Installation NOTICE BROKEN ENCLOSURE Do not exert more than 0 35 N m 3 1 lb in of torque when tightening the fastener s screws Failure to follow these instructions can result in equipment dama...

Страница 24: ...essories hardware or cables Remove power before wiring this product s power terminals Always use a properly rated voltage sensing device to confirm power is off Replace and secure all covers or elemen...

Страница 25: ...the individual wires are not twisted correctly the wires may create a short circuit The conductor type is solid or stranded wire Use copper wire rated for 75 C 167 F Power Connector Specifications Pow...

Страница 26: ...n these screws is 0 22 to 0 25 N m 1 95 to 2 2 lb in Do not solder the cable connection Doing so may either damage this product due to abnormal heat or cause a fire 5 Reattach the power connector plug...

Страница 27: ...r cable Power Supply Connections Use SELV Safety Extra Low Voltage circuit and LIM Limited Energy circuit for DC input The following shows a surge protection device connection Attach a surge protectio...

Страница 28: ...roduct as possible and make the wire as short as possible When using a long grounding wire replace the thin wire with a thicker wire and place it in a duct 1 Observe local codes and standards Short Ci...

Страница 29: ...t Ensure that power communication and accessory connections do not place excessive stress on the ports Consider the vibration in the environment when making this determination Securely attach power co...

Страница 30: ...disconnected Attaching the USB Holder Step Action 1 Attach the USB holder to the USB Type A Interface on this product Hook the clip on the right side of the USB holder into the slot beside the interfa...

Страница 31: ...32 English Connecting to the USB Interface 3 Attach the USB cover to fix the USB cable in place Insert the USB cover into the USB holder 1 USB holder 2 USB cable 3 USB cover...

Страница 32: ...en remove the USB cover 1 USB holder 2 USB cover 3 USB cable 2 Remove the USB cable from the USB Type A interface 3 As shown in the following illustration insert a screwdriver between this product and...

Страница 33: ...se a properly rated voltage sensing device to confirm power is off Replace and secure all covers or elements of the system before applying power to this product Use only the specified voltage when ope...

Страница 34: ...r 5 Insert the top of the RTC Battery Set first then press the bottom until it clicks to affix the RTC Battery Set onto this product 2 RTC Battery Set 6 Reconnect the power supply to this product NOTE...

Страница 35: ...d tools to remove or replace the battery Maintain proper polarity when inserting and connecting a new battery Failure to follow these instructions will result in death or serious injury Step Action 1...

Страница 36: ...ring the cloth tightly and wipe this product NOTICE EQUIPMENT DAMAGE Power off this product before cleaning it Do not use hard or pointed objects to operate the touch panel Do not use paint thinner or...

Страница 37: ...stall operate modify maintain service or otherwise alter this product except as permitted in this manual Unpermitted actions may impair the suitability of this product for Class I Division 2 operation...

Страница 38: ...ease access our site any time that you need help with a solution http www pro face com trans en manual 1001 html Please be aware that Digital Electronics Corporation shall not be held liable by the us...

Страница 39: ...40 English...