background image

-20-

The following items are included in the GLC's package.  Before using the
GLC, please confirm that all items shown here are present.

This unit has been carefully packed, with special attention to quality.
However, should you find anything damaged or missing, please contact
your local GLC distributor immediately.

„

„

„

„

„

 GLC Unit (1)

(GLC2300-LG41-24V/
GLC2300-TC41-24V)

„

„

„

„

„

 Installation Guide (1)

 <This Guide>

„

„

„

„

„

 Installation Fasteners (4)

Package Contents

Installation

Guide

„

„

„

„

„

 Installation Gasket (1)

„

„

„

„

„

 Screw Lock Terminal Block (1)

Содержание GLC2300-LG41-24V

Страница 1: ...ident can occur To prevent this be sure to set up external watchdog circuits that will monitor vital output signals Be sure to design a circuit that will supply power to the GLC s I O unit before star...

Страница 2: ...fety and reliability When using the GLC with transportation vehicles trains cars and ships disaster and crime prevention devices various types of safety equipment non life support related medical devi...

Страница 3: ...rm that the GLC s power cord is unplugged before either cleaning the GLC or at taching detaching the power terminal block screws When replacing the GLC s backlight be sure to unplug the unit s power c...

Страница 4: ...e a fire accident or malfunction GLC Operation and Maintenance Cautions Be sure to read the GLC s manual and on line help information carefully before performing program changes forced output or utili...

Страница 5: ...mounted at least 100 mm away from any other adjacent structures or machine parts If these conditions are not met the heat gener ated by the GLC s internal components may cause it to fail to meet UL st...

Страница 6: ...en carefully packed with special attention to quality However should you find anything damaged or missing please contact your local GLC distributor immediately GLC Unit 1 GLC2300 LG41 24V GLC2300 TC41...

Страница 7: ...am features 3 Changing to OFFLINE will release and stop ladder circuit program features Front Rear Bottom D Power Input Terminal Block E Expansion Unit Interface F CF Card Access LED G Serial Interfac...

Страница 8: ...CF Card is disabled CF Card with startup data required 2 Reserved Always OFF 3 Reserved Always OFF 4 This setting controls the forced closing of the CF Card cover Forced close enabled Forced close di...

Страница 9: ...ctor Dsub25 pinplugXM2A 2501 madebyOMRONCorp RecommendedCover Dsub25 pinCoverXM2S 2511 madebyOMRONCorp RecommendedCover Dsub25 pinCoverXM2S 2521 madebyOMRONCorp RecommendedScrew JackScrewXM2Z 0071 mad...

Страница 10: ...ector Pin Arrangement Pin Signal Name Description 1 CD Carrier Detect RS 232C 2 RD Receive Data RS 232C 3 SD Send Data RS 232C 4 ER Enable Receive RS 232C 5 SG Signal Ground 6 DR Data Set Ready RS 232...

Страница 11: ...is securely attached to the unit A gasket which has been used for a long period of time may have scratches or dirt on it and could have lost much of its dust and drip resistance Be sure to change the...

Страница 12: ...ghten it with a screwdriver Installation fastener Panel GLC Insertion Slots Insertion Slots Top Bottom Tightening the screws with too much force can damage the GP s plastic case The necessary torque i...

Страница 13: ...a screwdriver to remove the Power Input Terminal Block s clear plastic cover 3 Unscrew the screws from the middle three 3 terminals align the Ring Terminals and re attach the screws 4 Replace the Pow...

Страница 14: ...main circuit lines high voltage high current or input output signal lines Connect a surge absorber to handle power surges To reduce noise make the power cord as short as possible Depending on the inpu...