7
No LED indicators illuminated on battery
status indicator.
1.
Confirm that current is being delivered to the charger. Use a meter or test light to check
the AC power supply from its source through all connecting points up to the charger.
2.
The charger may be a powered by battery unit.
•
Use a meter to check that the battery pack is >= 8V DC.
•
Ensure a solid connection between the battery terminals and the DC charge
leads.
•
If the charger has ring terminals, ensure the red (or white) terminal is connected
to Po) and the Black is connected to Negative(
-
).
•
Please ensure no damage has been done to the DC charge leads.
3. Call technical support for further assistance. (615.471.5300)
The charge status indicator changes rapidly back and forth
from red to green or the green LED will not illuminate after excessive charg-
ing time (24 hours or more).
1.
Disconnect AC power from the charging system. This indication may signify a possible
battery problem.
2. Call technical support for further assistance. (615.471.5300)
A green LED was illuminated before disconnecting the power
from the charger, but upon reconnection the red LEDs appear and remain
on.
1.
This is normal operating procedure for the system. It indicates that a reanalysis of the
battery status was initiated and after a series of steps, the green LED will illuminate.