6
•
The
LED is solid whenever the charge cycle has terminated and the internal
circuitry has determined the batteries to be fully charged.
•
The
LED will blink during the finishing stage of the charge cycle. After the
completion of the charge cycle, the
LED will remain steady during the float
-
maintenance stage.
LED indicators scrolling from first
LED up to the
LED,
then the sequence repeats.
Special fault code. Call PCS Technical Support (615.471.5300)
LED indicators scrolling back and forth. First
LED to
LED—then from
LED back down to first
LED, then the sequence repeats.
This indicates the unit is connected through Bluetooth.
Your system provides an equalization stage every
30 days
while plugged in.
•
If the charger is normally disconnected from A/C after completing charge, equalization
can be accomplished by plugging back into A/C whenever this stage is desired. Battery
manufacturers recommend that equalization is done once a month in order to further
reduce sulfation on the lead plates of a battery, which helps promote longer battery
life.
•
Note: During this process the LEDs will go through their normal routine (
LEDs
counting up for % of charge along with the illuminated
LED Battery Type) and
then the
LED and
Battery Type LED will blink until the unit returns to
the maintenance mode and a steady
LED and steady
Battery Type
LED.