Never place the charger directly above or below the battery being charged; gases or fluids 

from the battery will corrode and damage the charger.  Locate the charger as far away from the 

 

battery as DC cables permit.   

 

  

Ne jamais placer le chargeur directment sous la batterie à charger ou audessus de cette dernière.  Les gaz ou les fluids qui 

sèchappent de la batterie peuvent entrainer la corrosion du chargeur ou l’endommager.  Placer le chargeur aussi loin de la 
batterie qui les cables c.c. le permettent. 

 

  

   

 

  

   If it is necessary to remove battery from vehicle to charge it, always remove grounded terminal 

from battery first.  Make sure all accesproes in the vehicle are off in order to prevent an arc. 

 

S’il 

est nécessaire de retirer la batterie du véhicule pour la charger, toujours d'ébrancher la borne 

 

de mise à la masse en premier.  S'assurer que le courant aux accessories du véhicule est coupe afin d’éviter la formation d’un 

arc. 

 

  

 

 

  

 

  Never smoke or allow an open spark or flame in the vicinity of the BATTERY the battery or engine. 

 

  

 

 

  

Ne jamais fumer près de la batterie ou du moteur et éviter toute étincelle ou flamme nue à proximité de ces dernie. 

 

  

 

 

  

 

 

  

 

   

 Working in the vicinity of a lead-acid battery is dangerous.  Batteries generate explosive 

 

gases 

 

during normal operation.  For this reason it is of the utmost importance that prior to each use of your charger, 

you 

  

read and follow the instructions provided exactly. 

 

  

Il est dangereux de travailler a proximité d’une batterie au plomb.  Les batteries produisent des gaz explosifs en service normal.  Il 

est aussi important de toujours relire les instructions avant d’utiliser le chargeur et de les suivre à la lettre.   

 

  

     

 

Suitable for servicing only when de-

energized.  Peut faire l’objet d’un entretien uniquement s’il est hors 

 

tension.

  

CHARGING INDICATIONS    

When your battery charging system is activated, the battery status indicator provides charging information utilizing five red 

LED indicators and one green LED indicator. 

 

  

 

 

  

Battery Type Indicators 

 

  

Two amber LED indicators are provided in order to display what type of battery the 
charger has been programmed to charge.  

NOTE:

 For information on reconfiguring 

the battery type, please contact technical support (

615.471.5300

). 

 

  

 

 

  

Battery System Percent Charged Indicators  

 

 

 

Four LED indicators are provided in order to display the progress of the charge   

cycle in percentage of charge.   Indications are as follows: 

 

  

 

 

  

1

ST

 Amber LED . . . .  . . . . . . .  Illuminated configured for Wet Cell and 

AGM*

 batteries 

 

  

2

ND

 Amber LED . . . . . . . . . . . . . Illuminated configured for Gel Cell batteries 

 

  

1

ST 

 RED LED . . . . . . . . . . . . .  Charging - Initial Charging Up To 30%  

 

  

2

ND

 & 3

RD

 RED LEDS  . . . . . . .  Charging - 60% Complete  

 

  

1

ST

, 2

ND

 & 3

RD

 RED LEDS. . . . Charging - 90% Complete  

 

  

BLINKING GREEN LED  . . . .  Finishing Stage (Note: Battery Type Indicator will also blink during this stage)  

 

  

STEADY GREEN LED  . . . . . . Charge Complete 

–Float/Maintenance Mode-On for 5 minutes and off for 60 minutes 

 

  

 

 

  

*We normally recommend our STANDARD Delta Volt profile for AGM Batteries.  There are some cases where certain 

AGM batteries are manufactured to different specifications and may need a special profile with a much lower finish 
voltage limitation.  In this case, we will do our best to accommodate your unique need. 

 

  

 

 

  

 

   

 

   

 

   

 

   

 

   

 

   

 

   

 

   

  

 

 

 

 

   

 

   

 

   

 

   

 

   

 

   

Содержание 4850OB

Страница 1: ...rger Models 4850OB 4875OB _______________________________________ 100620 70351 IMPORTANT NOTICE Please save and read these safety operating and installation instructions before installing or applying...

Страница 2: ...dditional Products Page 8 IMPORTANT SAFETY INSTRUCTIONS INSTRUCTIONS IMPORTANTES CONCERNANT LA S CURIT SAVE THESE INSTRUCTIONS This manual contains important safety and operating instructions for futu...

Страница 3: ...se Do not operate any charger when you are tired 5 Keep children away Children must never be allowed in the work area Do not let them handle machines tools battery chargers or extension cords 6 Keep w...

Страница 4: ...DANGEROUS Batteries generate explosive gases during normal battery operation For this reason it is of utmost importance that prior to each use of your charger you read this manual and follow the inst...

Страница 5: ...EVER charge a frozen battery Ne jamais charger une batterie gel e Assure that the area around your charger and batteries is properly ventilated Connect your extension cord with no AC Power present to...

Страница 6: ...tteries produisent des gaz explosifs en service normal Il est aussi important de toujours relire les instructions avant d utiliser le chargeur et de les suivre la lettre Suitable for servicing only wh...

Страница 7: ...ossible battery problem 2 Call technical support for further assistance 615 471 5300 PROBLEM A green LED was illuminated before disconnecting the power from the charger but upon reconnection red LEDs...

Страница 8: ...strial applications These chargers along with any chargers used outside of the USA will have a warranty period of 18 months from the date of retail purchase against defective materials and or workmans...