![pro bel V6402 HD Скачать руководство пользователя страница 68](http://html1.mh-extra.com/html/pro-bel/v6402-hd/v6402-hd_user-manual_1603965068.webp)
V6402, V6404, V6406,V6408
and V6418 HD converters
68
Issue 6
6.2
Initialization, Power On-Selftest & Error Messages
6.2.1
Board Initialization Sequence
Every time a board goes through a power-on cycle, either by re-seating the board in the rack or by
triggering the manual reset, a sequence of initialisation and self-test events is being carried out by the on-
board microcontroller.
If anything goes wrong, an error message is shown on the front panel display and program execution halts.
The following table shows the error messages and their meaning:
ERROR 01
Flash erasing failed
ERROR 02
Flash programming failed
ERROR 03
Main program checksum error after programming
ERROR 04
Bootloader checksum error after programming
ERROR 05
No program loaded and no valid upgrade in Flash Stick
F
la
sh
upg
rading
ERROR 06
Bootloader upgrade required but no valid bootloader upgrade in Flash
Stick
ERROR 07
STATUS stayed low after CONFIG pulsed low
ERROR 08
DONE stayed high after CONFIG pulsed low
ERROR 09
STATUS went low during configuration
F
P
GA
Load
ERROR 10
DONE stayed low after configuration
ERROR 11
Error writing to local EEPROM
ERROR 12
Error reading from EEPROM
ERROR 13
Initialising EEPROM to default data
Lo
c
al
EEP
R
OM
ERROR 14
Initialising parameters to default data
ERROR 15
Receive buffer overflow
ERROR 16
Receive overrun
ERROR 17
Receive framing error
Debug
P
o
rt
ERROR 18
Receive parity error