keyswitch input
·
no overrides
The buttons associated with the keypads can be assigned as <SOURCE>, <SALVO>,
<PROTECT> or <ALT-LEV> via the editor port.
64x32 with fully married control and no breakaway is the largest X-Y panel possible.
The source and destination keypads are assigned via the editor port.
Only BPS and BPD keypads (1 - 32) can be assigned to these panels. No dial-up
keypads are supported.
The same source association can be assigned to more than one button. The same
destination association can be assigned to more than one button.
Only one <SOURCE> button lamp will be lit and only one <DESTINATION> button
lamp will be lit.
The levels controllable can be assigned via the Editors.
The <level breakaway> buttons operate on a toggle on, toggle off basis where the
tally indicated on the panel is dictated by the number of level buttons on the panel.
For panels with no level buttons the tally indication for each destination association
is for the first controllable level with an assigned destination for the assigned
destination association. The source routed on that level is first compared against the
source on the same level of the source association assigned to the last <SOURCE>
button pressed. If a match is found then this buttons lamp is lit, otherwise, the other
buttons are checked in the same way until a match is found. The first match results
in that <SOURCE> button lamp being lit.
For panels with level buttons the tally indication is for the current most significant
active, controllable level (level 1 being the most significant level). Active levels are
indicated by the level button LED being illuminated. Only controllable levels can be
active (It is not possible to turn all level buttons off unless no levels are controllable).
If the current source association routed is assigned to more than one <SOURCE>
button then the tally indicated will be for either the last <SOURCE> button pressed or
the first button that source association is assigned to.
To have full 8 level breakaway control from only 4 physical level buttons a <ALT-LEV>
button is required. This function can be assigned to any button on the panel by
assigning the ‘level shift association’ to a button position on the source keypad. More
than one button can be assigned as <ALT-LEV>.
<PROTECT> buttons will only operate on the current active and controllable
destinations. To protect/unprotect a destination simply press the <PROTECT>