4407
Digital Audio Sample Rate Converter
Technical Manual
15
4.2
Electrical parameters
Normal electrical parameters are:
·
RS485
·
8 bit data
·
one stop
·
even parity
·
38.4kbaud
Normal transmitters used must be capable of running in parallel i.e. more than one
transmitter enabled, RS485 compatible. The group poll uses this feature.
4.3
Four wire and two wire operation
The 4407 is a full duplex four wire device. However due to the workings of the multi-
drop communication protocol where the controller initiates data flows, the 4407 can
be used as a two wire device with the following wiring modifications:
1
9
10
3
TX+
TX-
X+
4407 CONTROL CONNECTOR
FOUR WIRE FULL DUPLEX
RX-
RX+
X-
TWO WIRE MULTI-
DROP SYSTEM