4407
Digital Audio Sample Rate Converter
Technical Manual
9
The jumper (PL9) to select the AES reference termination values is located on the
5288 sample rate converter sub-module itself. The available selections are as follows:
AES reference termination values
PL9 settings (5288)
Description
75R
Use with unbalanced input to terminate signal with
75
W
HI-Z
Selects high impedance termination (Bridging
mode)
110R
Use with balanced inputs to terminate signal with
110
W
5288 termination jumpers
The termination impedance for the RS485 communications ports are set by PL5
(transmitter) and PL6 (receiver) as described in the following table:
RS485 transmit and receive termination values
PL5&6 settings (5288)
Description
HI-Z
Selects high impedance termination (Bridging
mode)
110R
Use to terminate signal with 110
W
Note: Do not leave the AES reference or RS485 inputs in high impedance with no
signal connected to avoid spurious input.
HI-Z110R
HI-Z110R
HI-Z
75R
110R
P 9
L
PL5
PL6
AES reference
termination
jumper
R 485
termination
jumpers
S
Содержание 4407