SYMPTOM

The device does not work (no LED 
function) after the batteries have 
been inserted

The device seems to be working 
correctly but no hygiene product is 
coming out of the hose

The device is dispensing 
too much or too little

The device is dispensing 
varying amounts

Flashing red/green light

POSSIBLE CAUSE

-  Batteries are empty
-  Batteries were not inserted  
  correctly

-  Battery case was not 
  inserted correctly

-  Device is not switched on

-  Container is empty
 - No container in the device
 - Pump is blocked
-  An unsuitable hygiene product 
  is being use

-  The dosage is not ideally set

-  The pump is blocked
-  The nozzle is blocked

-  The sensor pin is blocked; 
  the sensor cannot configure

SOLUTION

-  Insert new batteries
-  Re-insert batteries, paying 
  attention to the correct polarity

-  Re-insert the battery case, paying 
  attention to the correct polarity 

-  Turn on the device

-  Insert a full container
-  Insert a full container
-  Clean the pump
-  Clean the pump and use a 
  suitable hygiene product 

-  Set the dosage

-  Clean the pump
-  Clean the nozzle

-  Remove disruptive objects from 
  in front of the sensor or position 
  the device somewhere else 

Troubleshooting

130114_Prisman-Vario_ToucE_A5.indd   10

13.01.2014   14:17:44

Содержание Vario Touchless

Страница 1: ...dosing dispenser Wall dispenser for the hands free withdrawal of hand hygiene products such as disinfection cleaning and care agents Instructions for Assembly and Operation ENGLISH 130114_Prisman Vari...

Страница 2: ...asurable verification of effectiveness and has already proved itself many times over thanks to its ease of use in practice It is suitable for 500ml and 1000ml dispenser bottles and can carry liquids s...

Страница 3: ...o be adhered to should not have a distinctive texture For freshly painted surfaces ensure that the paint is completely dry The adhesive tape should be temperature resistant in the range 10 C to 40 C S...

Страница 4: ...with spray mist function provided is suitable for liquid hand disinfect ants and gels 1 Use the universal tool to pull the nozzle off the end of the pump 2 Push on the new nozzle Inserting the protect...

Страница 5: ...ady to function Fast flashing red The device is displaying the dosage once it has been set Flashing red and green The sensor pin is blocked The device should be checked for disruptive objects in the s...

Страница 6: ...water or replaced every three months To do this it should be completely emptied and free from product residues Cleaning the dispenser head 1 Turn the device off 2 Use the universal tool to push the hi...

Страница 7: ...ocked An unsuitable hygiene product is being use The dosage is not ideally set The pump is blocked The nozzle is blocked The sensor pin is blocked the sensor cannot configure SOLUTION Insert new batte...

Страница 8: ...EHV Directive 2004 108 EC Registration at the Stiftung Elektro Altger te Register WEEE reg No DE 90941274 Disposal Please recycle the packaging material appropriately If you take the device out of ope...

Отзывы: