A205 Mobile Hoist User Manual
Page
33
of
44
Part No. 999003 / Rev.2 / Nov 2017
21.
Recommended Cleaning Instruction
General cleaning
The exterior of the A205 can be cleaned using a damp soapy cloth for general
cleaning duties.
Please ensure the cloth is damp and not wet.
Ensure the
exterior of the device is dry after cleaning, dry using a clean dry cloth.
Care should always be taken when cleaning around electrical components
Disinfecting (if necessary)
Should the A205 require a more thorough clean, the use of the Actichlor
disinfectant product, which is widely available in tablet form and used
throughout the healthcare industry, is recommended for use to ensure a
thorough clean.
•
Please follow the manufacturers safety instruction for the use of the
cleaning product before use to ensure safe use for the operator and the
patient.
•
Ensure the cloth is
damp
before the cleaning process.
DO NOT
use
a wet cloth over electrical systems.
•
Be careful not to let water ingress into the device as although the
device is IP rated, it is not water tight.
Application is through a clean soaked (but damp) cloth applied to
wipe the device down
Used in the following dilutions to ensure an effective clean:
•
Actichlor dissolvable chlorine tablets provide a concentration of
1000 ppm of available chlorine (0.1%) per 1 tablet
•
1 tablet (1.7g formed tablet (x1)) will create a virucidal solution,
diluted in 1 litre of water to provide effective means to clean a
“Dirty” device. This is also ideal for use after an outbreak of the
Norovirus / winter vomiting and can be used as a precaution
against C.Diff. It is effective against viruses, bacteria, spores,
yeasts and moulds.
•
The contact time against the outer components of the device
should be for 5 minutes to prevent any virucidal infections without
a degradation to the functionality of the device. 5 minutes is a
recommended contact time. The device can withstand a longer
contact period but the 5 minute recommendation as a minimum
must be followed to provide an effective cleaning regime.
•
Blood spills should be dealt with by an increased concentration of
the solution – please refer to the instructions on the
manufacturers product labelling.
Содержание A205
Страница 1: ...Aluminium Mobile Hoist A205 User Manual ...
Страница 39: ...A205 Mobile Hoist User Manual Page 39 of 44 Part No 999003 Rev 2 Nov 2017 ...
Страница 40: ...A205 Mobile Hoist User Manual Page 40 of 44 Part No 999003 Rev 2 Nov 2017 ...
Страница 41: ...A205 Mobile Hoist User Manual Page 41 of 44 Part No 999003 Rev 2 Nov 2017 ...
Страница 42: ...A205 Mobile Hoist User Manual Page 42 of 44 Part No 999003 Rev 2 Nov 2017 ...
Страница 43: ...A205 Mobile Hoist User Manual Page 43 of 44 Part No 999003 Rev 2 Nov 2017 User Notes ...