541-531revD-EN
9
Printed in USA 10/10 © 2010
Product Holding Bin
DHB-BK41/43
Set Maximum Transfer Time
A. The SET MAXIMUM TRANSFER TIME menu is used to set the amount of time allowed to make a product transfer from one pan to another.
B. Press and hold the PRINCE CASTLE LOGO button, then immediately press and hold the MENU/ENTER button until the display shows one of
the programming menus.
C. Use the UP or DOWN Arrow button to scroll to the
max xFR TIME
(Set Maximum Transfer Time) menu.
1
PRINCE CASTLE LOGO Button
MENU/ENTER Button
A. Press and release the MENU/ENTER button to enter the Set
Maximum Transfer Time menu.
B. The display shows
max xFR :20
. This shows a value of 20
seconds.
2
A. To change the time, use the UP or DOWN Arrow button to
scroll to the desired time. When the desired selection is
displayed, press the MENU/ENTER button to enter the
selection.
B. Press and release the PRINCE CASTLE LOGO button at any
time to exit the Program Mode and return to the Run Mode.
NOTE: If the MENU/ENTER button has not been pressed to save
any changes, the program will revert to the original time.
3
Product Linking
Any Timer Bar (except bun holding timers) can be linked to others (see Special Programming Mode, this page). If Timer Bars are set to the same link
group, any product started in any bar of the same group will be compared to all other products in the same group, and its LED color will be determined
based on all timers in the group with the same product (not just with all timers on its own Timer Bar).
Special Programming Mode
A. Press and hold the PRINCE CASTLE LOGO button then immediately press and hold the MENU/ENTER button. Hold both buttons for six
seconds. The displays will change to show the first menu — depending on model.
B. Press and release the UP and DOWN Arrow buttons to scroll through the list of Special Modes.
1
PRINCE CASTLE LOGO Button
MENU/ENTER Button
ENTR
Set Link Group
A. When the displays show
SET LINK GRPx
ENTR,
the X indicates the currently assigned Link Group. Press and release the MENU/
ENTER button to set the Link Group Mode.
B. The link group number (X) will flash. Press and release the UP and DOWN Arrow buttons to change the group number. The maximum
number allowed is 3, and the minimum is 0. When a Timer Bar is assigned to Link Group 0, it is isolated and not associated with any other
Timer Bar (linking is disabled).
C. When the desired link group is displayed, press and release the MENU/ENTER button to save it. The program will revert to Set Link Group
Mode.
2