Pasta Dispensers 

 

 

 

The Pasta Dispenser assembly is composed of 
three removable parts: one hopper, one hopper 
cover and one loading box. No tools are needed to 
assemble these parts. 

 

 

The Pasta Dispenser is a precision machine and 
should be handled with care. 

 

Lift the cover from the Pasta Dispenser assembly and 
slide the cover down inside the loading box as shown. 

 

 

A.  Fill loading box with approx. 1 lb. of long-cut 

pasta. 

B.  Fill hoper with up to 14 lbs. of the same long-cut 

pasta. 

 

Use only pasta recommended by Prince Castle. 
Using other types of pasta or food may cause 
severe damage and void all warranties and 
maintenance contracts. 

 

 

 

A.  Remove the loading box cover, allowing pasta to 

fall into the hopper. 

B.  Place loading box cover firmly on top of loading 

box. 

The long-cut Pasta Dispenser is now ready for use. 

 

It is recommended that you keep the hopper 
supplied with at least two pounds of pasta at all 
times. 

 

 

 

Fill each of the two short-cut past dispensers with up 
to 14 lbs. of pasta. 
The short-cut Pasta Dispensers are now ready for use. 

 

Procedure Complete 

 

 

 

 

 

 

Loading 

Box

Loading 

Box 

Cover 

Loading 

Box

 

Hopper

 

 

Loading 

Box 

Cover 

Printed in USA  0404 © 2004 

630-500 

Содержание 630-ROM4

Страница 1: ...and or mileage Travel mileage is limited to 100 miles 200 kilometers round trip one trip warranty from an authorized service agency or its sub service agency This warranty is subject to the following exceptions conditions Use of any non genuine Prince Castle parts voids this warranty All labor shall be performed during regular work hours Overtime premium will be charged to the buyer Damage caused ...

Страница 2: ...pable of withstanding 340 lbs weight of unit This unit is completely pre wired and thoroughly tested prior to shipment All wiring and hookups shall be done without opening the unit Place unit on the counter The counter must be designed to fit the size and support the weight of the unit The unit must be level to insure proper function To level the unit use only the adjustable leveling feet no shims...

Страница 3: ...s indicated in the Pre Installation requirements the user must provide a circuit breaker between the main power source and the unit Refer to nameplate for rating The unit is wired and tested by the factory to operate only with a single phase power configuration with one ground for main load and circuit control To avoid severe electrical shock provide grounding in accordance with N E C requirements...

Страница 4: ...g cut pasta Use only pasta recommended by Prince Castle Using other types of pasta or food may cause severe damage and void all warranties and maintenance contracts 3 4 A Remove the loading box cover allowing pasta to fall into the hopper B Place loading box cover firmly on top of loading box The long cut Pasta Dispenser is now ready for use It is recommended that you keep the hopper supplied with...

Страница 5: ...thoroughly before first time use Wash trays and all strainers frequently to prevent starch accumulation Switching the Unit On 1 2 Ensure that all the previous steps were executed properly before proceeding A Visually and manually check that the Blow Down valve is closed B Check that water supply line is fully opened Verify that the on off switch on the back of the unit is in ON position When unit ...

Страница 6: ...as filled the Sight Glass halfway WARNING EXPLOSION DAMAGE INJURY HAZZARD The Sight Glass indicator should NEVER rise above the full position If so immediately shut down the unit and call for repair WARNING EXPLOSION DAMAGE INJURY HAZZARD Do NOT turn either of the two red handled Sigh Glass turn valves These are used by authorized service personnel ONLY Hold the blue I O button for approx 3 secs T...

Страница 7: ...omplete Daily Blow Down Procedure IMPORTANT It is extremely important to fully understand and perform these maintenance procedures This procedure should be performed with caution preferably at the end of the workday For the first few days only TWO blow downs per day are recommended to clean the inside of the boiler A daily blow down is essential maintenance for a steam generator It lengthens the l...

Страница 8: ...for about 3 secs to turn the unit on C Fill the boiler with water Procedure Complete Daily or Weekly Clean Up 1 IMPORTANT This process is semi automatic and must be followed exactly Frequency of this procedure depends upon frequency of usage Failure to comply with this procedure may void the unit warranty Remove the four funnels from the top of the unit IMPORTANT Use a standard long handle 3 5 scr...

Страница 9: ... start the automated cleaning cycle The top gates automatically close The chambers are flushed and rinsed and the bottoms gates are closed When the cleaning cycle is finished approx 30 secs the unit automatically shuts down 6 7 A When finished ensure that all foreign objects are removed from the chambers B Replace the funnels Slide the three dispensers forward to their normal position Ensure that ...

Отзывы: