Steamer 625-50
5
Rev G
Printed in USA
1010
© 200
3
7
Steamer
625-M
FY
4
Pour a solution of McD
®
Delimer™ (one packet per
16 oz.
of hot
water) into the steam chamber. Let solution soak for at least 15
minutes
. Continue with next step while soaking.
NOTE: Use one packet for monthly
cleaning procedure and dispose of
the unused solution once the
procedure is completed.
In hard water areas that require
daily, bi-weekly or weekly clean-
ing, it is possible to use partial
packets. Two teaspoons of
McD
®
Delimer™ can be dissolved in a
small coffee cup with 100ml of hot
water. The packet can be used for
4 applications.
5
A.
Use brushes to clean the water tube.
B
. Dip brush in warm water or deliming solution and
Insert the brush about 1" into water tube and then remove.
2
A. Remove spatula.
B. Remove the top
plate by carefully
sliding it forward
and out of the unit.
C. Remove the
venturi plate.
Cleaning - Monthly PM Tasks
The following equipment is required:
•
McD
®
All Purpose Super Concentrate (APSC)
•
McD
®
Sink Pak Sanitizer McD
®
APC
(Australia only)
•
McD
®
Delimer™ (as required)
•
Clean sanitized towel
•
Protective (insulated) gloves
Top Cover
Top Plate
Venturi Plate
Spatula
1
While wearing protective gloves, remove the top cover by
pulling up and off the unit.
3
A. Wash top cover, top plate, spatula, and venturi plate in a
solution of McD
®
APSC / APC made up in the back sink.
B. Rinse with clean water, and then sanitize in a solution of
McD
®
Sink Pak Sanitizer.
C. Let air dry.
CAUTION
Do not spray directly on the unit or use abrasive cleaners!
WARNING
Turn the unit off and unplug the power cord from the electrical recep-
tacle. Proceed with caution, unit is still hot!
CAUTION
This unit is not watertight. Do not clean with a water jet/jet spray. Do
not immerse the unit in water.
Do not use abrasive materials such as scrapers, steel wool, etc. to
clean the spatula or steam chamber.
IMPORTANT. It is not recommended
to leave open packets lying around.
While wearing protective gloves:
NOTE:
In areas that are affected by very hard water, a reverse osmosis
(RO) water filtration system is an option to reduce accumulation
of mineral deposits in th
e
steamer. Contact either
Cuno,
a KES or
Coca-Cola for recommendations.
A
.
Rinse with clean water.
B
.
Wash all external surfaces of the steamer with a solution of
McD® APSC / APC. Using the McD® APSC / APC spray
bottle, spray directly onto a clean sanitized towel and wipe
the unit clean.
C
. Reassemble the unit.
6
C
.
Repeat for 30 seconds.
Insert brush here.