B.2 Parameters in the Advanced menu

Advanced System Configuration Submenu

 

 The initial values have been unchanged.

Setting

Advanced System Configuration

BIOS Work Space Location:

Expansion ROM Area

(  )Top of Base Memory

Memory Redundancy:

Disabled

(  )Sparing

CPU Mismatch Detection:

Enabled

(  )Disabled

CPU Timeout Counter:

Disabled

(  )Enabled

CPU Frequency (GHz):

Automatic

 For Xeon® Processor 5110/5130/

   E5310 unavailable

 For Xeon® Processor 5050

(  )1.99  (  )2.16

(  )2.32

(  )2.49

(  )2.66

(  )2.82

(  )2.99

 For Xeon® Processor 5160

(  )2.00  (  )2.33

(  )2.66

(  )3.00

 For Xeon® Processor X5355

(  )1.60  (  )1.87  (  )2.14  (  )2.40

(  )2.67

Hyper-Threading: *1

Disabled

(  )Enabled

Limit CPUID functions:

Disabled

(  )Enabled

CPU Thermal Management

*2

Enhanced

(  )Standard

CPU Halt Mode:

Enhanced

(  )Standard

NX Memory Protection:

Disabled

(  )Enabled

CPU MC Status Clear:

Next Boot

(  )Enabled (  )Disabled

Enhanced SpeedStep:  *3

Disabled

(  )Enabled

Virtualization Technology:

Disabled

(  )Enabled

Hardware Prefetch:

Enabled

(  )Disabled

Adjacent Sector Prefetch:

Enabled

(  )Disabled

High Precision Event Timer:

Disabled

(  )Enabled

I/OAT:

Disabled

(  )Enabled

*1

Appears when Xeon® Processor 5050 is installed.

*2

Not appears when Xeon® Processor 5050 is installed.

*3

Not appears when Xeon® Processor 5110/5130/E5310 is installed.

Power On/Off Submenu

 

 The initial values have been unchanged.

Setting

Power On/Off

Power Off Source
   Software:

Enabled

(  )Disabled

   Power Button:

Enabled

(  )Disabled

Power On Source:

BIOS Controlled

(  )ACPI Controlled

   Remote:

Enabled

(  )Disabled

   LAN:

Enabled

(  )Disabled

   Wake Up Timer:

Disabled

(  )Enabled

      Wake Up Time:  *1

[00:00:00]

      Wake Up Mode:  *1

Daily

(  )Monthly

         Wake Up Day:  *2

1

(  )[1

31]

Power Failure Recovery:

Previous State

(  )Always Off (  )Always On

*1 Appears when "Enabled" is selected for [Wake Up Timer].
*2 Appears when "Monthly" is selected for [Wake Up Mode].

Item

Initial value

Item

Initial value

11

Содержание TX200 S3

Страница 1: ...ur server A Configuration Sheets of Hardware Use this form to record the hardware configuration and various settings of your server B Configuration Sheets of BIOS Setup Utility Parameters Use this for...

Страница 2: ...ft Windows Server 2003 Standard x64 Edition Windows Server 2003 Standard x64 Edition Microsoft Windows Server 2003 Enterprise x64 Edition Windows Server 2003 Enterprise x64 Edition Microsoft Windows 2...

Страница 3: ...17 C 6 Parameters in the Network Settings 18 C 7 Parameters in the SNMP Trap Alerting 19 C 8 Parameters in the Email Alerting 19 C 9 Parameters in the User Management 20 C 10 Parameters in the BIOS Te...

Страница 4: ...1 GB PG RM1CD PG RM1CE Slot 3A 3B 2 GB PG RM2CD PG RM2CE 4 GB PG RM4CD PG RM4CE SCSI ID 5 or 6 5 or 6 5 Memory Bank 1 Internal LTO2 unit PG LT201 Internal LTO3 unit PG LT301 Internal hard disk unit b...

Страница 5: ...stalled position Xeon Processor E5310 2x4MB FSB1066MHz Xeon Processor X5355 2x4MB FSB1333MHz Slot 1 Slot 2 Slot 1 Slot 2 Slot 2 Xeon Processor 5160 4MB FSB1333MHz Slot 1 Slot 1 Xeon Processor 5130 4MB...

Страница 6: ...re starting the BIOS Setup Utility press the Ctrl Alt Delete keys simultaneously and restart the system The initial values have been unchanged Setting System Time HH MM SS Displays Sets present time S...

Страница 7: ...n the boot sequence Diskette CD ROM Drive Standard Diskette Hard Drive Hard Drive Bus 02 Dev 0E PCI RAID Adapter Legacy LAN Card Alternate Device Legacy LAN Card The initial values have been unchanged...

Страница 8: ...Plug Enabled Disabled ATA Controller Config Links to ATA Controller Config submenu Diskette Controller Enabled Disabled Mouse Controller Auto Detect Disabled Enabled Onboard Video Enabled Disabled LAN...

Страница 9: ...tion Submenu The initial values have been unchanged Setting PCI SLOTS Configuration PCI Slot 1 Configuration Option ROM SCAN Enabled Disabled PCI Slot 2 Configuration Option ROM SCAN Enabled Disabled...

Страница 10: ...e 3 Auto Disabled IRQ3 IRQ4 IRQ5 IRQ6 IRQ7 IRQ9 IRQ10 IRQ11 IRQ12 IRQ14 IRQ15 PCI IRQ Line 4 Auto Disabled IRQ3 IRQ4 IRQ5 IRQ6 IRQ7 IRQ9 IRQ10 IRQ11 IRQ12 IRQ14 IRQ15 PCI IRQ Line 5 Auto Disabled IRQ3...

Страница 11: ...Boot Enabled Disabled Enhanced SpeedStep 3 Disabled Enabled Virtualization Technology Disabled Enabled Hardware Prefetch Enabled Disabled Adjacent Sector Prefetch Enabled Disabled High Precision Event...

Страница 12: ...mask Gateway address 000 000 000 000 Gateway address The initial values have been unchanged Setting Setup Password Not installed Displays whether or not the setup password is set System Password Not...

Страница 13: ...bled Enabled Memory Scrubbing Disabled Enabled CPU Status Links to CPU Status submenu Memory Status Links to Memory Status submenu Console Redirection Links to Console Redirection submenu 1 Appears wh...

Страница 14: ...ule 3B Enabled Failed 1 Disabled 2 1 Appears when memory error occurs This can be changed to Enabled only 2 Appears when memory module is removed Console Redirection Submenu The initial values have be...

Страница 15: ...Upload Not Upload Upload The initial values have been unchanged Setting Restart Gives a direct instruction on power control of the server Power Restore Pollicy BIOS setting is Always Power off reflect...

Страница 16: ...sec 9 FAN PSU2 continue shutdown and power off Deley sec 10 FAN PSU2 continue shutdown and power off Deley sec The initial values have been unchanged Setting Temperature Sensor Information Sets the o...

Страница 17: ...y BIOS setting is minutes reflected Action with retry counter zero BIOS setting is Power Off reflected Boot Diagnostic IDE Disk Boot PXE Boot iRMC Remote Image Retry counter BIOS setting is reflected...

Страница 18: ...t Port 3172 Telnet Drop Time 600 SSH Port 22 Telnet enabled Disabled Enabled Disabled For other ports the settings are only displayed Unchangeable DHCP Configuration Register DHCP Address in DNS Enabl...

Страница 19: ...ver 0 0 0 0 SMTP Port 25 Auth Type None None SMTP AUSH RFC2554 Auth UserName 1 Auth Password 1 Displays Confirm Password 1 Displays Secondary SMTP Server Configuration SMTP Server 0 0 0 0 SMTP Port 25...

Страница 20: ...ser Information ID Name 2 admin 2 The User Name is displayed that is created by New User Clicking UserName displays a setting window for each UserName The default settings or the settings that are con...

Страница 21: ...econdary User Description User02 Description Email Address User02 domain com Fan Sensors WARNING NONE CRITICAL WARNING ALL Temperature Sensors WARNING NONE CRITICAL WARNING ALL Critical Hardware Error...

Страница 22: ...S Format Prefered Mail Server Automatic Automatic Primary Secondary User Description Email Address Fan Sensors WARNING NONE CRITICAL WARNING ALL Temperature Sensors WARNING NONE CRITICAL WARNING ALL C...

Страница 23: ...de Standard Enhanced Console Redirection Port Serial 1 Serial 2 Serial Port Baudrate 1200 2400 4800 9600 19200 38400 57600 115200 Serial Port Flow Control None XON XOFF CTS RTS Terminal Emulation VT10...

Страница 24: ...e the I O port address space that can be selected in the expansion card indicates that some or all of the 16 bytes that follow the marker address may be used space selected for default indicates that...

Страница 25: ...HDB75A 73 4GB 3 Disk group 0 Spare disk 0 Disk group Spare disk 1 Disk group Spare disk 2 Disk group Spare disk 3 Disk group Spare disk 4 Disk group Spare disk 5 Disk group Spare disk Installation HDD...

Страница 26: ...d BBU LD DG RAID 0 RAID 1 RAID 5 RAID 10 Write Through Write Back Bad BBU LD DG RAID 0 RAID 1 RAID 5 RAID 10 Write Through Write Back Bad BBU LD DG RAID 0 RAID 1 RAID 5 RAID 10 Write Through Write Bac...

Страница 27: ...disk 6 CH ID Physical pack Spare disk 7 CH ID Physical pack Spare disk 8 CH ID Physical pack Spare disk 9 CH ID Physical pack Spare disk 10 CH ID Physical pack Spare disk 11 CH ID Physical pack Spare...

Страница 28: ...ite Back LD Array RAID 0 RAID 1 RAID 5 RAID 10 Write Through Write Back LD Array RAID 0 RAID 1 RAID 5 RAID 10 Write Through Write Back LD Array RAID 0 RAID 1 RAID 5 RAID 10 Write Through Write Back LD...

Страница 29: ...tent of Definition of the Logical Drive Installed PCI slot HDD model name HDD capacity Logical drive capacity e g 0 PG HDB75A 73 4GB 34464 MB e g 1 PG HDB75A 73 4GB 34464 MB 0 1 Installation HDD Slot...

Страница 30: ...anually Delete Existing RAID Array RAID Level Number of Disks HotSpare Yes No NTFS FAT Auto setting MB Execute Do not execute Boot OS Data Disk Make copies when installing multiple disks Partition Mak...

Страница 31: ...onents R2 Component source media is available in local CD ROM drive R2 Component source media is available on a remote share Default GMT 01 00 Amsterdam Berlin Bern Rome Stockholm Vienna Use default D...

Страница 32: ...fied DNS server address only when specified Use WINS Use WINS server address DHCP only when selected to use Use NetBIOS setting from the DHCP Server Use NetBIOS over TCP IP Do not use NetBIOS over TCP...

Страница 33: ...server address only when specified Use WINS Use WINS server address DHCP only when selected to use Use NetBIOS setting from the DHCP Server Use NetBIOS over TCP IP Do not use NetBIOS over TCP IP Inte...

Страница 34: ...tall pro vision install directory of WIMSDE full pass of a log file Common Log File System Microsoft NET Framework2 0 English Microsoft NET Framework2 0 International Microsoft NET Framework2 0 Langua...

Страница 35: ...Internet Information Services web DAV publishin World Wide Web Server World Wide Web WWW Service World Wide Web Server Internet Information Services internet data connector World Wide Web Server Inte...

Страница 36: ...end Receive only when specified Physical Datalink and sub network End to End Application Internet Authorize the following access permits to terminal service users License mode Current mode for termina...

Страница 37: ...in name Domain NetBIOS name Complete DNS name of the new domain Create a new child domain under the existing domain tree only when selected User name Password Domain User name Password Domain Complete...

Страница 38: ...800 600 1024 768 1156 864 1280 1024 1600 1200 60 70 72 75 80 85 100 16 colors 256 colors High Color 16bits True Color 24bits True Color 32bits Name BitsPerPel continued Product ID Display setting Reso...

Страница 39: ...IP address additional only when added Subnet mask additional only when added Default gateway additional only when added DNS domain name only when specified DNS server address only when specified Use...

Страница 40: ...de table Calculator Paint Word pad Document templates Script debugger Object packager Desktop wallpaper Free cell Mine sweeper Pinball Solitaire Simple Network Management Protocol SNMP Domain Name Sys...

Страница 41: ...e Active Directory details setting only when DNS is selected Install Active Directory Active Directory type Database location Log location SYSVOL folder location Access permit compatibility with Windo...

Страница 42: ...plication from Local CD Install selected application from Remote Server When installing from remote server Install Do not install Remote Source Path Remote Username Remote Password Setting PowerChute...

Страница 43: ...PRIMERGY TX200 S3 PG OS DATE TIME Phase of accident Yes No Attached paper Name Product ID Environment LAN WAN config Accident Sheet What did you do what message etc 43...

Страница 44: ...s to third party copyrights or other rights arising from the use of any information in this manual No part of this manual may be reproduced in any form without the prior written permission of Fujitsu...

Отзывы: