Chapter 2 Checking before OS Installation
2.3.6 Cautions for Manual Installation
■
Checking Onboard Array Controller Setting
Disk array configuration on the onboard SCSI array controller must be completed before the OS is
installed. To check the onboard SCSI array controller configuration, start up the SCSI Setup Utility. For
more details, refer to "8.3 SCSI Setup Utility" (
pg.215). If a disk array is not configured on the
onboard SCSI array controller, the normal SCSI configuration is established.
■
Free Space Required for Installation
The partition where the OS is installed must have enough free space for obtaining memory dump. For
more details, refer to "5.1 Memory Dump/Paging File Setting" (
■
Cautions on Restarting
In the course of installation, a message appears to indicate that the setup program restarts. Wait until it
restarts.
For more details on background operations, refer to "Onboard SCSI RAID User's Guide".