MANUALE D'INSTALLAZI ONE / USER MANUAL
42
Once the device is turned on, the pellet load must be completely burned
according to the cycle set by the
MANUFACTURER
and the process must
not be interrupted.
NOTE
During the first ignition, the appliance will exhale, for a few hours, the smell of paint.
Recall that these odors are annoying but are not harmful.
After each operating cycle, it is normal for a minimum residual amount of ash to remain
in the tank, which must be removed before starting the next cycle.
7.3
–
ERROR SIGNALS*
LED color
Description of the error
Alternating Red / Green
Ignition failure. After 150 seconds, the flue gas probe has
not reached the set temperature. Disconnect the
Powerbank and repeat the ignition phase.
Alternating red / blue
The fan is stopped because it is clogged or faulty. Clean
the fan duct or replace the component. Contact the after-
sales service
Alternating red / amber
Flue gas probe disconnected or interrupted / faulty.
Check the correct connection or replace the component.
Contact the after-sales service
*
To clear errors, simply disconnect the Powerbank.