CLEARING A JAMMED FASTENER
CAUTION
: Always disconnect tool from air supply before clearing a jam.
• Remove all remaining fasteners from the magazine.
• Open the latch on the front end of the nose and use a pair of needle nose pliers or a flat
screwdriver to remove bent fastener from guide body (Fig. 22, 23).
MAINTENANCE
CLEAN AND INSPECT DAILY
Clean and inspect tool daily. Carefully check for proper operation of trigger and safety
mechanism. Do not use the tool unless both the trigger and the safety mechanism are
functional, or if the tool is leaking air or needs any other repair.
CAUTION
: Disconnect tool from air supply before cleaning and inspection. Correct all
problems before operating.
Wipe the tool clean and inspect for wear or damage. Use non-flammable cleaning solutions
to wipe exterior of tool only if necessary. Do not soak tool with cleaning solutions. Such
solutions can damage internal parts
Keep all screws tight. Loose screws can cause personal injury or damage tool.
If tool is used without an in-line oiler: put 5 or 6 drops of pneumatic tool oil into the air inlet
of the tool at the beginning of each workday.
SERVICE AND REPAIRS
Disassembly of the tool must be done in a clean environment. Some parts can be easily
damaged if disassembled with improper tools or by inadequatemethods. Maintenance should
only be performed by trained personnel. Use only genuine PRIMATECH replacement parts.