9
Flow Rates
Subject: Flow capacity through ECO VALVE, back pressure/pressure sustaining and
pressure relief valves.
Under continuous flow conditions: @
100 PSI
with ambient temperature water with the valve
set@ 50PSIG.
1/4
” valve
17 USGPM
3/8
” valve
18 USGPM
1/2
” valve
19 USGPM
Note: Capacities will increase with pressure. (If pressure is doubled, flow rate will
approximately double)
For capacities of valves with pulsating flow use approximately 1/3 of the above given flow
values.
TEMPERATURE EFFECTS:
Thermoplastics and thermosets will decrease in tensile strength as the
temperature increases; therefore, the working pressure must be reduced accordingly. The following factors
will apply:
Temperature Correction Factors
Thermoplastics
Operating
{Factors}
Temperatures
NR
–
Not Recommended
*
–
Recommended for continuous
drainage pressure only
F
C
PVC
CPVC
PP
PVDF
70
21
1.00
1.00
1.00
1.00
80
27
0.90
0.96
0.97
0.95
90
32
0.75
0.92
0.91
0.87
100 38
0.62
0.85
0.85
0.80
110 43
0.50
0.77
0.80
0.75
115 46
0.45
0.74
0.77
0.71
120 49
0.40
0.70
0.75
0.68
125 52
0.35
0.66
0.71
0.66
130 54
0.30
0.62
0.68
0.62
140 60
0.22
0.55
0.65
0.58
150 66
NR
0.47
0.57
0.52
160 71
NR
0.40
0.50
0.49
170 77
NR
0.32
0.26
0.45
180 82
NR
0.25
*
0.42
200 93
NR
0.18
NR
0.36
210 99
NR
0.15
NR
0.33
240 116
NR
NR
NR
0.25
280 138
NR
NR
NR
0.18
Содержание ECO-25