Introduction 

 

The following instructions are to provide information on the Installation, operation and maintenance 
of ECO Valve, diaphragm style valves, manufactured by Primary Fluid Systems Inc. The valves are 
designed to help improve the performance and safe operation of most positive displacement 
pumps.  
 
Various materials of construction are available dependent on the requirements of the application 
and the type of fluids being transferred. 
 
The valve(s) are factory set at 50 PSIG with a field adjustment range of 7-150 PSIG.  Other factory 
set pressure ranges (within the range of the valve) is available upon request. 
 

Features of ECO Valve: 

  PVC, PP, CPVC (Corzan), PVDF and 316L S/S wetted construction 

  PTFE laminated to EPDM backed diaphragm standard 

  Optional Viton or EPDM wetted diaphragm materials 

  Only one elastomer is present in the wetted end 

  Turn down handle limits pressure to 150 PSIG 

  Locking adjustable pressure screw 

  Color-coded caps indicate size at a glance 

  Built-in gauge port on both sides of valve body (pre-drilled & threaded optional) 

  Specially designed spring provides consistent pressure adjustments through the range (7-

150 PSIG) 

  Eco valve is available in several configurations to meet your needs, such as threaded, 

socket, flanged, union in DIN, BSPT and American Standard 

  Built-in downstream manual air release, for ease of pump priming 

  Built-in anti-siphon 

 

Back Pressure Valve/Anti-siphon: 

 
Diaphragm Back Pressure Valves serve two primary functions.  The first is to provide a constant 
discharge pressure on the pump, which improves the performance, efficiency and consistency of 
the delivered volume.  Secondly, the valve performs as an anti-siphon mechanism against positive 
or negative pressures in the downstream line.  The valve is designed to allow for the venting of air 
into the downstream pipeline.  This provides for easier priming of metering pumps that function 
under a suction lift.  This is accomplished by a simple adjustment of the handle.  
 
The valve comes complete with a gauge port located on both sides of the valve body; the ports are 
normally not drilled or tapped for a gauge connection. 

(See gauge installation instructions on 

page 5) 

 
 
Caution: 
The gauge port is solely for the installation of the gauge and must not be used for the 
bleeding or venting of the system.  Improper operation of the valve and/or hazardous 
consequences could result

. (See gauge installation instructions) 

 

 

Содержание ECO-25

Страница 1: ...ation and instructions that must be read understood and followed to ensure that the equipment is installed operated and serviced in an appropriate manner Failure to do so before using may result in hazardous consequences and or improper operation Manufactured by PRIMARY FLUID 1050 Cooke Blvd Burlington Ontario L7T 4A8 SYSTEMS INC Tel 905 333 8743 Fax 905 333 8746 Call Toll Free 1 866 324 6422 E Ma...

Страница 2: ...sure adjustments through the range 7 150 PSIG Eco valve is available in several configurations to meet your needs such as threaded socket flanged union in DIN BSPT and American Standard Built in downstream manual air release for ease of pump priming Built in anti siphon Back Pressure Valve Anti siphon Diaphragm Back Pressure Valves serve two primary functions The first is to provide a constant dis...

Страница 3: ...he valve body the ports are normally not drilled or tapped for a gauge connection See gauge installation instructions on page 5 Caution The gauge port is solely for the installation of the gauge and cannot be used for the bleeding or venting of the system Improper operation and or hazardous consequences could result See gauge installation instructions Pressure Relief Valves Reason for Selection an...

Страница 4: ...alled on the discharge line of a pump and should be located as close as possible to the metering pump The valve is of a two port design and is required to be installed on a branch tee for piping back to the supply tank or feed side of the pump Never install shut off isolation valves between pump discharge and in line pressure relief valves When using in conjunction with a back pressure control val...

Страница 5: ...n of the diaphragm on the seat To adjust the valve to relieve air or gas downstream 1 Back off lock nut located beneath the colour coded handle 2 Turn handle counter clockwise until approximately 1 inch of thread is exposed 3 At this adjustment the spring has relieved all tension from the diaphragm allowing air or gas to be vented downstream ...

Страница 6: ... examples only Consult your engineering department for the appropriate installation for your application or call the factory for advice Example A Solenoid Driven Pumps Rated Under 150 psig Example B System arrangement for solenoid driven above 150 psig or motor driven pumps ...

Страница 7: ...7 Exploded View Back Pressure Pressure Relief Valve 1 4 ECO 25 3 8 ECO 38 1 2 ECO 50 ECO Valves ...

Страница 8: ... steel Connection A NPT B BSPT C S W N A D S W Metric E Flg ASME F Flg DIN G Union Thr d Material TFE PTFE EPDM E EPDM V viton Size 25 1 4 S S valve 38 3 8 S S valve 50 1 2 S S valve Colour G Green 1 4 valve B Brown 3 8 valve Y Yellow 1 2 valve O Ring seal V viton E EPDM T PTFE encapsulated viton Connection NPT NPT BSPT BSPT SOC S W Imperial SOC M S W Metric Size 25 1 4 S S valve 38 3 8 S S valve ...

Страница 9: ...trength as the temperature increases therefore the working pressure must be reduced accordingly The following factors will apply Temperature Correction Factors Thermoplastics Operating Factors Temperatures NR Not Recommended Recommended for continuous drainage pressure only F C PVC CPVC PP PVDF 70 21 1 00 1 00 1 00 1 00 80 27 0 90 0 96 0 97 0 95 90 32 0 75 0 92 0 91 0 87 100 38 0 62 0 85 0 85 0 80...

Страница 10: ...10 ...

Страница 11: ...nts and instructions set forth herein are based on the best information and practices known to Primary but it should not be assumed that every acceptable safety procedure is contained herein Of necessity Primary cannot guarantee that actions in accordance with such statements and instructions will result in the complete elimination of hazards and it assumes no liability for accidents that may occu...

Страница 12: ...12 Notes ...