Q: When I start my autofocus routine, focusing graph looks flat instead of creating the V-curve.
A: This happens when, in the autofocusing routing of the software you choose, the step size is too small. Correct
step size may depend also on your focuser so you may have to try different values, but, by considering the SESTO
SENSO 2 resolution of 0,7 microns per step, you can start with 200.