background image

PRIMA LIGHTING - FIT II INSTALLATION MANUAL

CAUTION

1. Failure to properly install low voltage electrical products may void the warranty. Please ensure the proper 

electrical connections as follows:

• Follow instruction guidelines when wiring and installing tran

sformers.

Firmly connect the transformer’s secondary leads to the FIT II System track as described in the power

feed instruction sheets.

ting connections at all conductive 

Be sure the lamp is firmly seated in the socket.

Check to ensure that no wires, cables or packing materials are crossing both conductors of the 

FIT II track.

2. Make sure all power connections are tight. Follow this procedure to ensure proper connection:

   

• Read all transformer instruction sheets before installation.

• Turn on the power only after system installation is complete.

• 60 minutes after power-up, check for excess heat at power con

nection areas.

• Tighten any connections that feel hot and assure to use 10 AWG THHN single standard wire from 

transformer to powerfeed. The use of this wire is to maintain the standard 25 amp capacity.

• Do not use Romex cable or MC rigid cable for secondary wire c

onnections.

For long distance remote connections, please refer to the voltage drop table in the back of this 

instruction manual.

3.

Measure voltage after the installation is complete.

Secondary voltage for 12V system should be between 11.3V 

to 11.7V with 85% to 90% load without dimmer, and for 24V system should be between 22.6V to 23.4V  

Since electronic transformers run at a higher frequency, the u

se of a high-end voltage meter such as  

Fluke 87 is recommended.

4

.

Always turn off the power and allow the system to cool before at

tempting any adjustments such as moving 

powerfeeds, adjusting pendant cable lengths, moving trackheads or changing light bulbs.

5.

Prima Lighting includes lamps for each fixture we ship. The lamps included are top quality and well-

known name brands. We will normally send 50W MR16 for spotlights and 50W Xelogen G6.35 lamp for 

pendants unless otherwise specified differently in the catalog. P

rima will also ship according to customers’ 

specific lamp type or wattage per order. Lamps are complimentary

, thus we will not offer free replacements, 

nor will we issue any credit for lamps. However, customers may 

purchase lamps from us and receive standard

lamp warranty.  We always encourage our customers to purchase r

eplacement lamps directly from us 

when replacements are needed. 

6

. If systems are ordered without transformers, all warranties are void and complimentary lamps will not be 

 

 

 

 

 

   

 

 

 

 

 

 

 

supplied.

11

.

If you experience problems or irregular function of the system,

 stop the installation immediately and contact 

Prima Lighting Customer Service for assistance.

 

 

 

   

 

13615 Marquardt Ave. Santa Fe Springs, CA 90670
Ph. 562-407-3079 . Fx. 562-407-3069
www.primalighting.com

 FIT II interconnecting joints.

with 85% to 90% load without dimmer. Magnetic transformers may 

be tested with most voltage meters. 

7.  

The maximum permissible load allowed on any Prima Rail circuit 

is 25 amps. The rail can be operated at 12 volts 

with a 300W maximum load or at 24 volts with a 600W maximum loa

d.

8.  

9. 

 When cleaning FIT II System track, be sure to use a clean damp

  cotton cloth.

Prima Lighting systems are listed by ETL. Our system products a

re only listed when used as a complete system. All 

components, including transformers, must be provided by Prima Lighting. The substitution of Prima products with 

another manufacturer’s product will render the listing completely void. Prima Lighting is removed from liability 

 

and any insurance to which you may be entitled will be jeopardized.

Questions or problems you can’t find answered here? Call 1-562-407-3079 during regular business hours 

(Monday-Friday 7:00-4:00pm PST).

CAUTION! Bulbs, metal, and other parts of elements may become hot. Use protective gloves and adjust 

 

  

 

  

 

 

 

 

 

 

 

 

 

elements by their coated handles and cords.

 

REV. 052416

10.  Do not apply any  paint material over our tracks and connectors.

Содержание FIT II

Страница 1: ...ORTANT SAFETY INSTRUCTIONS IF YOU HAVE ANY QUESTIONS REGARDING THE INSTALLATION OF THIS PRODUCT PLEASE CALL PRIMA CUSTOMER SERVICE AT 1 562 407 3079 INSTALLATION INSTRUCTION A READ ALL OF THESE INSTALLATION INSTRUCTIONS BEFORE INSTALLING THE FIT II SYSTEM B DO NOT INSTALL THIS SYSTEM IN DAMP OR WET LOCATIONS C DO NOT INSTALL THIS SYSTEM OR ANY PART WHICH CONTAINS EXPOSED WIRES LESS THAN 7 FEET FRO...

Страница 2: ...ity and well known name brands We will normally send 50W MR16 for spotlights and 50W Xelogen G6 35 lamp for pendants unless otherwise specified differently in the catalog Prima will also ship according to customers specific lamp type or wattage per order Lamps are complimentary thus we will not offer free replacements nor will we issue any credit for lamps However customers may purchase lamps from us...

Страница 3: ...ting elements and reset the breaker 2 Attempt to turn the system on If the system still trips look inside the transformer housing and make sure all connections are secure and that there is no short If the system stays on you most likely have a problem with one of the lighting elements Re install one element at a time and check if the system works to find the defective element Ensure that the lighti...

Страница 4: ...CUTTING BLADE Be sure to deburr and clean all cuts prior to final assembly fit II system track connector powerfeed basics B1 B2 Connectors are available for extending track length turning corners or creating intersections in the run Great care must be taken to ensure the connector is installed properly FIT II track is constructed of an aluminum housing which doubles as the neutral conductor The sl...

Страница 5: ...ssure creates a solid and secure mounting IMPORTANT Do not attempt to slide the adapter to other locations on the track length after it is installed The adapter must be completely removed from the track slot and reinstalled at the new location Insert the adapter into the track slot Apply pressure and rotate 90º clockwise After rotation adapter rests inside track slot Rotate knurled locking ring cl...

Страница 6: ... point Mounting screws Anchors E Track Support End Mount Insert the Track Support End Mount to the end of the track and tightened the screw with a screwdriver Insert the screw anchor and tighten the screw Be sure that the items indicated below are included in the package Insert the Track Support End Mount to the end of the track and tighten it with a screw driver Do both ends before mounting it on...

Страница 7: ...he side 22 79122 or the top 22 79123 Insert the connector into open end of a FIT track length Secure the powerfeed by tightening the set screws with a flat head screwdriver at the top and bottom of the connector Insert the transformer s low voltage secondary leads into the power entry holes on the connector Using the supplied hex wrench secure the transformer leads by tightening two set screws for...

Страница 8: ... conductive 22 79132 or non conductive 22 79133 inserts into the conductor hole on one of the track lengths Insert the top and bottom cover half way into the same track length and secure by tightening the set screws with a flat head screwdriver Connect the second track length and secure by again tightening the set screws with a flat head screw driver There should be no space between the connected ...

Страница 9: ...r installation to ensure proper installation and conductivity 3 Remove the power feed before moving to ensure finish of track Voltage Temperature Readings Voltage 11 3V 1 11 7V w 85 to 90 load Temperature 80 90 F Room Temperature This additional piece is necessary for Fit II application 13615 Marquardt Ave Santa Fe Springs CA 90670 Ph 562 407 3079 Fx 562 407 3069 www primalighting com fit II syste...

Страница 10: ...y questions installation Adhere to all local and national electrical codes prior to installation IMPORTANT USE ONLY LOW VOLTAGE DIMMERS WITH MAGNETIC TOROIDAL TRANSFORMERS Prima recommends the use of 10AWG THHN wire to maintain 25 amp capacity Note Using a dimmer may shorten the secondary length distance Class I ELECTRONIC TRANSFORMERS ARE DIMMABLE Prima recommends the use of 10AWG standard wire o...

Отзывы: