background image

120 V / 60 Hz mains supply. The installation must be in accordance with 

2

3

THANK YOU

Thank you for choosing this innovative Pridiom dehumidifier.

This instruction manual describes the many benefits and advanced features 
that this unique product has to offer.

This dehumidifier is a tough, industrial unit designed to be used almost any-
where that dry air is required. Desiccant/Absorption dehumidifiers are especially 
suited to applications where low relative humidities are needed and work well 
over a wide tempera-ture range.

Pridiom specializes in complete indoor humidity control. Our world class products 
incorporate the latest technological developments and are designed to create 
a quality environment.

It is important that you read these instructions carefully before installing 
and using your new dehumidifier.
Please keep them in a safe place for future reference.

SAFETY

For safety reasons, read this information carefully before operating. Persons 
who are not familiar with this type of product must not use it.

This appliance must be grounded and should only be connected to a grounded

the regulations of the country where the unit is used.

This unit is designated for indoor operation.

• 

The dehumidifier is safe, however, as with other electrical appliance, use it 
with care.

• 

This appliance is not intended for use by persons (including children) with 
reduced physical, sensory or mental capabilities, or lack of experience 
and knowledge, unless they have been given supervision or instruction 
concerning the use of the appliance by a person responsible for their 
safety.

• 

Children should be supervised to ensure that they do not play with the 
appliance.

• 

Do not clean the dehumidifier by spraying it or immersing it in water.

• 

Do not insert any object into the opening of the dehumidifier.

• 

Disconnect from the mains before cleaning the unit or any of its compo-
nents.

• 

Never connect to an electrical outlet using an extension cord. If an outlet 
is not available, one should be installed by a licensed electrician.

• 

Any service other than regular cleaning or filter replacement should be 
performed by an authorized service representative. Failure to do so could 
result in a loss of warranty. Your dehumidifier is supplied with an electrical 
cable and a grounded plug. Should it be necessary to replace this plug at 
any time, you must use a grounded electrical plug.

Warning!  Never operate this appliance if it has a damaged cord or plug. If the 
supply cord is damaged, it must be replaced by an approved service repre-
sentative or a similar qualified person in order to avoid any hazards.

There should be direct access to the electrical plug after connecting the 
power!

Do not use your dehumidifier under the following conditions:

This product is not 

made for DI

repair

If the power cable 

wires are frayed 

or cut

When small 

children may be 

left unattended

Where the power 

cable may be 

damaged

Where it may 

be damaged by 

chemicals

If there is a risk of 

liquid falling on 

the unit

Содержание PGD970DES

Страница 1: ...PGD970DES USER MANUAL VER 1 261112 www pridiom com...

Страница 2: ...quality environment It is important that you read these instructions carefully before installing and using your new dehumidifier Please keep them in a safe place for future reference SAFETY For safet...

Страница 3: ...ss of warranty Your dehumidifier is supplied with an electrical cable and a grounded plug Should it be necessary to replace this plug at any time you must use a grounded electrical plug Warning Never...

Страница 4: ...copic membranes absorb almost all of the moisture creat ing an extremely dry airstream this airstream is discharged directly through the Dry Air Outlet A second fan pushes a separate air stream Regen...

Страница 5: ...sealed ball bearing units REGEN HEATER BANK The PGD970DES uses a ceramic PTC type regen heater PTC Positive Temperature Coefficient heaters are base on a semi conductor that changes resist ance as it...

Страница 6: ...t the dry air stream into the room to be dried The Process Air Inlet inlet should also be ducted to the room to give a re circulation effect Note As the Wet Air Out discharge is warm and very humid en...

Страница 7: ...or humidistat via the Remote Humidistat Connector this can be accessed by removing the dust cap A connection plug is available on request ATTENTION The remote connector is mains voltage The remote swi...

Страница 8: ...1 5kW Phase 1ph Dimensions in 22 04 x 13 85 x 13 58 Weight NET 43 6 lbs Weight GROSS 50 7 lbs Operating Temperature 4 F 104 F Disposal This marking indicates that this product should not be disposed w...

Страница 9: ...9 OUTLET DUCT REGEN AIR INLET DUCT PROCESS AIT DUCT WET AIR OUTLET DUCT 4 92 in 3 15 in 4 92 in 13 85 13 85 3 15 in 22 04...

Страница 10: ...r Heater Bank The PTC heater bank is maintenance free however if it becomes blocked with dust e g if it has been running without inlet air filter it can cleaned by vacuum cleaner or low pressure compr...

Страница 11: ...ed Check ductwork if fitted is not obstructed Check voltage level Check fan is working If the unit is noisy Check fan operation Check rotor drive Check for loose screws Low Dehumidifying Effect Check...

Страница 12: ...n Fan Capacitor DH06 P006 Desiccant Rotor DH01 P009 Rotor Drive Belt DH01 P005 Rotor Drive Pulley DH01 P007 Rotor Drive Motor Gearbox DH01 P006 Heater Bank DH01 A010 Over Heat Protector DH01 P015 Main...

Страница 13: ...EMOTE SWITCH HUMIDISTAT OPTIONAL FAN CAPACITOR OVER HEAT PROTECTOR MANUAL RESET AMMETER HOUR METER HOUR METER E E M REG FAN FAN CAPACITOR TERMINAL BLOCK MAINS LEAD MAINS SWITCH REMOTE HUMIDISTAT SWITC...

Страница 14: ...14 Y...

Страница 15: ...15 Y...

Страница 16: ...16 201 266 6775 info pridiom com Englewood NJ 07631 www pridiom com...

Отзывы: