POSITIONING

The PGD970DES is designed only for indoor use however, it can be placed 
either inside or outside the room needing to be dried.

Internal Positioning:
When positioning the unit inside the room, place centrally, ensuring inlet and 
outlet ducts are clear of obstruction.
If required, ducts can be connected to the outlet and/or inlet to direct the dry-
ing to specific areas.
The Wet-Air-Out and Regen-Air-In MUST be ducted to and from outside the 
room.

External Positioning:
When positioning the unit outside the room, connect ducting to the outlet to 
direct the dry air stream into the room to be dried. The Process-Air-Inlet inlet 
should also be ducted to the room to give a re-circulation effect.

Note:
As the Wet-Air-Out discharge is warm and very humid ensure it is directed 
where it will have no adverse effect on the immediate environment.

All ducting lengths should be kept to a minimum - longer lengths will reduce 
performance.

The Wet-Air-Out is warm and humid, when a duct is attached, condensation 
may form on the inside of the duct. This duct should slope downwards away 
from the unit to prevent any condensation running back into the unit. 

CONTROLS

Controls are positioned on the front of the 
unit next to the air outlet duct.

• 

Power Switch

• 

Ammeter

• 

Hour Meter

• 

Remote Humidistat Switch

• 

Remote Humidistat Connector

OPERATION

Stand-Alone Operation:
Connect unit to suitable mains supply
Ensure ‘Remote Humidistat’ switch is set to ‘OFF’ position
Switch ‘Power’ switch to ‘ON’ ( I ) position.
The fan will start and the Ammeter reading will rise. (The ammeter indicates 
the current taken by the PTC heater bank. Its reading will depend on the ‘Pro-
cess’ air temperature and the ‘Regen’ airflow. Typically, it will indicate between 
4 and 6 amps - this will reduce if the airflow is low or the Process air tempera-
ture is high.

Remote Operation:

For remote operation it is necessary to connect a switch or humidistat via the 
‘Remote Humidistat Connector’ - this can be accessed by removing the dust 
cap. A connection plug is available on request.

ATTENTION - The remote connector is mains voltage!
The remote switch/humidistat should be connected between pins 1 and 3. 
The Earth pin is connected to ground and can be used if required. (see wiring 
diagram)
The ‘Remote Humidistat’ switch should be set to the ‘ON’ position.
The unit will now operate according to the state of the remote switch.

Air Filter:
Your unit has an inlet air filter that should be checked periodically and 
if necessary cleaned. It can be cleaned with a vacuum cleaner or washed in 
mild detergent.

ATTENTION:  Do not run the unit without a filter fitted as dust will impair the 
performance of the Desiccant Rotor.

Содержание PGD970DES

Страница 1: ...PGD970DES USER MANUAL VER 1 261112 www pridiom com...

Страница 2: ...quality environment It is important that you read these instructions carefully before installing and using your new dehumidifier Please keep them in a safe place for future reference SAFETY For safet...

Страница 3: ...ss of warranty Your dehumidifier is supplied with an electrical cable and a grounded plug Should it be necessary to replace this plug at any time you must use a grounded electrical plug Warning Never...

Страница 4: ...copic membranes absorb almost all of the moisture creat ing an extremely dry airstream this airstream is discharged directly through the Dry Air Outlet A second fan pushes a separate air stream Regen...

Страница 5: ...sealed ball bearing units REGEN HEATER BANK The PGD970DES uses a ceramic PTC type regen heater PTC Positive Temperature Coefficient heaters are base on a semi conductor that changes resist ance as it...

Страница 6: ...t the dry air stream into the room to be dried The Process Air Inlet inlet should also be ducted to the room to give a re circulation effect Note As the Wet Air Out discharge is warm and very humid en...

Страница 7: ...or humidistat via the Remote Humidistat Connector this can be accessed by removing the dust cap A connection plug is available on request ATTENTION The remote connector is mains voltage The remote swi...

Страница 8: ...1 5kW Phase 1ph Dimensions in 22 04 x 13 85 x 13 58 Weight NET 43 6 lbs Weight GROSS 50 7 lbs Operating Temperature 4 F 104 F Disposal This marking indicates that this product should not be disposed w...

Страница 9: ...9 OUTLET DUCT REGEN AIR INLET DUCT PROCESS AIT DUCT WET AIR OUTLET DUCT 4 92 in 3 15 in 4 92 in 13 85 13 85 3 15 in 22 04...

Страница 10: ...r Heater Bank The PTC heater bank is maintenance free however if it becomes blocked with dust e g if it has been running without inlet air filter it can cleaned by vacuum cleaner or low pressure compr...

Страница 11: ...ed Check ductwork if fitted is not obstructed Check voltage level Check fan is working If the unit is noisy Check fan operation Check rotor drive Check for loose screws Low Dehumidifying Effect Check...

Страница 12: ...n Fan Capacitor DH06 P006 Desiccant Rotor DH01 P009 Rotor Drive Belt DH01 P005 Rotor Drive Pulley DH01 P007 Rotor Drive Motor Gearbox DH01 P006 Heater Bank DH01 A010 Over Heat Protector DH01 P015 Main...

Страница 13: ...EMOTE SWITCH HUMIDISTAT OPTIONAL FAN CAPACITOR OVER HEAT PROTECTOR MANUAL RESET AMMETER HOUR METER HOUR METER E E M REG FAN FAN CAPACITOR TERMINAL BLOCK MAINS LEAD MAINS SWITCH REMOTE HUMIDISTAT SWITC...

Страница 14: ...14 Y...

Страница 15: ...15 Y...

Страница 16: ...16 201 266 6775 info pridiom com Englewood NJ 07631 www pridiom com...

Отзывы: