TEMP Button    :

   Push this button to decrease the indoor 

o

O

temperature setting in 1 F increments to 62 F.

FP Button: 

During the heating operation(only when the 

setting mode is HEAT), press this button and the unit will 
operate at high fan speed with the temperature automatically 

O

O

set to 8 C/46 F. The display window of indoor unit will display
   FP .  Press  the buttons of ON/OFF, MODE, FAN SPEED, 
TEMP UP/DOWN, TIMER ON/OFF, SLEEP or FP while 
operating will cancel the FP function.  

RESET Button:

  When  you press the recessed RESET button,  

all current settings are cancelled and the control will return to 
the initial settings.

SLEEP Button: 

Press this button to go into the Energy-Saving

operation mode. Press it again to cancel. This function is only 
can be used on COOL, HEAT and AUTO mode and maintain the
most comfortable temperature for you.

2

1

6

ON/OFF Button:

  Push  this button to start operation,  push

 the button again to stop operation.

9

TEMP Button      :

  Push this button to increase the indoor 

o

O

temperature setting in 1 F increments to 86 F.

2

AIR DIRECTION Button: 

Used to change the louver 

movement and set the desired up/down air flow direction. 

O

The louver changes 6  in angle for each press.

MODE Selection Button:

  Each time the button is pressed, 

the operation mode is shifted in the direction of the arrow:

AUTO

COOL

DRY

HEAT

FAN 

3

FAN SPEED Button:

  Used to select the  Fan Speed in four steps-

 AUTO LOW 

MED or  HIGH. Each time the button is pressed,

the fan speed mode is shifted.

8

TIMER ON Button: 

Press this button to initiate the auto-on time 

sequence. Each press will increase the auto-timed setting in 30
minutes increments. When the setting time displays 10h, each 
press will increase the auto-timed setting 60 minutes increments.
To cancel the auto-timed program, simply adjust the auto-on time
to 0.0.

10

11

4

5

NOTE:  

While the unit is running under SLEEP operation mode, it would 

be canceled if you press the MODE,FAN SPEED or ON/OFF button.

NOTE:   FP   button is available for Model RG51M1/EU1 
             only.

1

Model

Transmission Distance

Rated Voltage

RG51M5/(C)EU, RG51M1/EU1

8m 

3.0V(Dry batteries Lr03

2)

Remote Controller Specification

Performance Features

Features of Remote controller buttons

1. Operating Mode:  AUTO

COOL

 DRY

    HEAT(Cooling only model without) and FAN .
2. Timer Setting Function in 24 hours.
3. Indoor  Setting  Temperature Range: 
4. Full function of LCD (Liquid Crystal Display) 

Fig. 1

TEMP

AUTO 
COOL
DRY
HEAT

FAN
HIGH
MED
LOW

MODE

FAN SPEED

TIMER ON

SLEEP

ON/OFF

TIMER OFF

        AIR 
 DIRECTION

RESET LOCK

1

2

4

5

6

7

3

8

9

10

11

12

13

14

15

Environment

SET TEMPERATURE(  F)

        SWING

        LED
    DISPLAY

        TURBO

SWING Button:

  Push this switch button to activate auto 

swing feature of the horizontal louver. Push it again to stop.

7

O

O

62 F~ 86 F

O

O

O

23 F~140 F

        FP

NOTE

Please do not select HEAT mode if the machine you 

purchased is cooling only type. Heat mode is not supported by 
the cooling only appliance.

NOTE: 

Press and hold        and         buttons together for 3 seconds will 

O

O

alternate the temperature display between the   C &  F scale.

Содержание CR052-RG51M5

Страница 1: ... Please read this Owner s Manual carefully before operation Save this manual in a safe place for future reference The design and specifications are subject to change without prior notice for product improvement Consult with the sales agency or manufacturer for details ...

Страница 2: ...ion 3 5 After setting the TIMER there will be a one half second delay before the remote controller transmits the signal to the Air Conditioner Then after approximately another 2 seconds the signal h disappears and the set temperature will re appear on the digital display Change the TIMER To change the TIMER ON OFF time just press the corresponding TIMER button and reset the time To cancel the TIME...

Страница 3: ...W MED or HIGH Each time the button is pressed the fan speed mode is shifted 8 TIMER ON Button Press this button to initiate the auto on time sequence Each press will increase the auto timed setting in 30 minutes increments When the setting time displays 10h each press will increase the auto timed setting 60 minutes increments To cancel the auto timed program simply adjust the auto on time to 0 0 1...

Страница 4: ... LR03X2 1 To install the batteries slide the back cover of the battery compartment and install the batteries according the direction and shown on the Remote Controller 2 To replace the old batteries use the same method as mentioned above Install Replace Batteries NOTE All signs shown in the Fig 2 is for the purpose of clear presentation But during the actual operation only the re lative functional...

Страница 5: ...ows TIMER ON the last set time for the starting operation and the signal h will be shown on the DIGITAL DISPLAY area You are now ready to reset the time to START the operation 1 2 Push the TIMER ON button again to set desired unit start time 1 3 After setting the TIMER ON there will be a one half second delay before the remote controller transmits the signal to the air conditioner Then after appro...

Отзывы: