US Jet 3 Ultra/RevC/Jun03
www.pridemobility.com
35
V I I I . O P E R A T I O N
Battery Connector
This connects the VSI to the power chairs batteries.
Thermal Rollback
The VSI controller is equipped with a thermal rollback circuit. The circuit monitors the temperature of the controller, which
roughly translates to motor temperature. In the event that the VSI controller becomes excessively hot (above 140° F),
motor current (amperage) is reduced. For every degree above 140° F, the motor current limit is reduced by .55 amps until
the VSI controller reaches 158° F, at which time the current output is reduced to zero. This reduces your power chairs
power, which could also reduce your power chairs speed, and allows the electrical components and motors to cool
down. When the temperature returns to a safe level, your power chair resumes its normal operation.
VSI Error Codes
The VSI controller is designed with the users safety as the prime consideration. It incorporates many sophisticated self-
test features which search for potential problems at a rate of 100 times per second. If the VSI detects a problem either in
its own circuits or in the power chairs electrical system, it may decide to stop the power chair, depending on the severity
of the problem. The VSI is designed to maximize the users safety under all normal conditions. The table below identifies
the individual error codes. Error codes are displayed as a rapid flashing of the lights. If you get one of these error codes,
contact your authorized Pride Provider.
FLASHING
DIAGNOSIS AND SOLUTION
LIGHTS
1
The battery needs charging or there is a bad connection to the battery. Check the connections to
the battery. If the connections are good, try charging the battery.
2
The left motor has a bad connection. Check the left motor connection.
3
The left motor has a short circuit to a battery connection. Contact your authorized Pride Provider.
4
The right motor has a bad connection. Check right motor connection.
5
The right motor has a short circuit to a battery connection. Contact your authorized Pride Provider.
6
The power chair is being inhibited by the battery charger. Unplug the battery charger.
7
A joystick fault is indicated. Make sure that the joystick is in the neutral (center) position before
turning on the controller.
8
A controller system fault is indicated. Make sure that all connections are secure.
9
The parking brakes have a bad connection. Check the parking brake and motor connections.
Make sure the controller connections are secure.
10
An excessive voltage has been applied to the controller. This is usually caused by a poor battery
connection. Check the battery connections.