36
www.pridemobility.com
Blast/Rev F/Feb03
V I I I . O P E R A T I O N
Thermal Rollback
The Remote Plus is equipped with a thermal rollback circuit. This circuit monitors the temperature of the motors, power module, and
remote. In the event that any of them become excessively hot (above 122° F), motor voltage is reduced. For every degree above 122°
F, the voltage is reduced by 5 volts. This reduces your power chairs speed and allows the electrical components to cool down. When
the temperature returns to a safe level, your power chair resumes its normal speed.
Trouble Codes
In addition to indicating the current state of battery charge, the battery condition meter can also indicate possible problems with
your power chair. The battery condition meter has ten lights. The lights provide information by the number of lights that are
flashing. If any of the meter lights are flashing rapidly, the controller may be indicating a fault. For instance, if the first light is
flashing rapidly, the battery voltage is nearly depleted. The following is a list of the possible errors signified by the rapidly
flashing meter. When you get a trouble code, contact your authorized Pride provider.
FLASHING LIGHTS
DIAGNOSIS
SOLUTION
10
High Battery Voltage
Check batteries.
9
Solenoid Brake Fault
Check motor/brake wiring.
8
Possible Controller Fault
See authorized Pride provider.
7
Possible Joystick Fault
See authorized Pride provider.
6
Inhibit Active
Unplug charger. Check connections.
5
Right Motor Wiring Fault
Check right motor wiring.
4
Right Motor Disconnected
Check right motor wiring.
3
Left Motor Wiring Fault
Check left motor wiring.
2
Left Motor Disconnected
Check left motor wiring.
1
Low Battery Voltage
Check batteries/battery wiring.