..\Manuals\RCI-100-MDM rev.B.doc
Page 10 of 16
Downloading & Uploading Configuration Data:
To download the internal configuration data of the RCI-100-MDM or upload new
configuration data it must first be place in PROGRAMM mode.
1. Turn the power switch OFF.
2. Locate configuration jumper H7 on the modem
board and insert jumper H7-1 only.
3. Locate Communication Select jumper H5 on the
modem board and move the two jumpers from the
NORM position into the PROG position.
4. Connect the serial cable to the RS-232 connector on the modem
board and to your serial port on your computer.
5. Make sure you have your serial port software (see HyperTerminal
above) running on your computer.
6. Turn the power switch back on and wait at least 5 seconds.
You can now download and upload configuration data as may times as
necessary until the unit is configured properly. We suggest that you
download the configuration data again after you have uploaded it to make
sure that the RCI-100-MDM accepted it properly.
Upon completion
turn the power switch OFF again,
remove jumper H6-1,
move jumpers H5 back to the NORM position, disconnect the serial cable
and finally
turn the power switch back on.
Download Configuration Data:
1. Make sure your serial software is ready to capture incoming serial
data (see File Capture using HyperTerminal above)
2. Press the DIAL button on the modem board.
3. The RCI-100-MDM will now send all of its internal configuration
data, which is being captured, to a file by the computer. The red TX
(transmit) LED will light or blink during this operation and you should
see the data on your screen. When the red TX LED stops flashing the download is complete.
Note: If you are not receiving any data on your
computer one possible reason may be that your
Transmit and Receive lines in the RS-232 cable
maybe crossed
Straight-Thru Cable
Null-Modem Cable