background image

Page B4

ITC-79-FTF

Available Models:

ITC-79-FTF: Frequency Isolator

Outputs: TTL, 24VDC, Dry Contact

ITC-79-FTF-DIV: Frequency Isolator with Divider

Outputs: TTL, 24VDC, Dry Contact
Function: Divide Input by Division Factor

ITC-79-FTF-BUF: Frequency Isolator with Buffer

Outputs: TTL, 24VDC, Dry Contact
Function: Store Pulses & Release Slowly

Dimensions:

Calibration:

Calibration is made easy by multi
turn potentiometers with test
jacks for meter connection.

Connection:

Manufactured By:

www.pribusin.com

[email protected]

CANADA:

Pribusin Inc.
101 Freshway Dr. Unit 57
Concord, Ontario, L4K 1R9
Ph: (905) 660-5336
Fx: (905) 660-4068

USA:

Pribusin Inc.
743 Marquette Ave
Muskegon, MI 49442
Ph: (231) 788-2900
Fx: (231) 788-2929

Subject to change without notice

Содержание ITC-79-FTF Series

Страница 1: ...alled Relay Function Frequency to Frequency Isolator Option ITC 79 FTF Power If special or required BUF Frequency Pulse Buffer Response Time 100 microsec DIV Frequency Divider Input 0 10 VDC Threshold...

Страница 2: ...ducts or all non standard products may not be returned for restocking Pribusin Inc warrants equipment of its own manufacture to be free from defects in material and workmanship under normal conditions...

Страница 3: ...iturn potentiometers All potentiometers have a test point where a voltage of 10 to 10 VDC indicates the threshold level as 100 to 100 This allows for easy field calibration with the instrument running...

Страница 4: ...Outputs TTL 24VDC Dry Contact Function Store Pulses Release Slowly Dimensions Calibration Calibration is made easy by multi turn potentiometers with test jacks for meter connection Connection Manufact...

Страница 5: ......

Страница 6: ......

Страница 7: ...ut Type Determine the type of input that is to be applied to the ITC 79 FTF choices are Voltage Dry Contact AC or DC Coupled Follow the instructions below depending on which input type you are using V...

Страница 8: ...e ON and OFF threshold levels The ON and OFF LED s indicate which portion of the pulse is currently being received on frequencies above 30 Hz both LED s appear to be on simultaneously In the above exa...

Страница 9: ...1 The release time is encoded in binary which means that up to 65536 216 combinations of release rates are selectable Jumper position H1 1 is equivalent to 0 1 msec position H1 2 equals 0 2 msec H1 3...

Страница 10: ...ows H1 1 out H1 5 out H1 9 in H1 13 out H1 2 out H1 6 in H1 10 in H1 14 out H1 3 out H1 7 in H1 11 out H1 15 out H1 4 in H1 8 in H1 12 out H1 16 out The jumpers that are inserted carry the binary weig...

Страница 11: ......

Отзывы: