Powering the Unit

To charge the battery, plug the supplied charging cable into the USB-mini socket [14] and then plug 

into any full-sized USB socket, for example on a computer or phone charger, or alternatively plug a 

dc power supply into the auxiliary power socket [15]. Prior to using an auxiliary power source, it is 

important to check that its polarity and voltage are in accordance with the specifications given at the 

end of this booklet.

Irrespective of the charging source, the charging LED [13] lights green and once fully charged, the LED 

is extinguished. Charging takes approximately 3 hours if the battery is completely flat and the unit 

may be used as normal while charging. If the charging LED should flash red during use and the unit 

emit short beeps, it’s time to recharge.

Connecting the unit to devices

FREEDOM

 may be connected to up to four devices via the four sockets [5-8] and the supplied cables. 

Occasionally you may encounter a device which has a switch input which uses a connector other than a 

3.5mm socket, in which case one of the supplied cables can be adapted. More cables can be purchased 

from  Pretorian-  the  part  number  is  E070010.  You  do  not  need  to  consider  the  way  in  which  each 

respective device is connected to ground or mains earth since each socket in 

FREEDOM

 is electrically 

isolated from the others.

The unit is capable of switching up to 30V and must 

NEVER

 be used to switch anything above this 

voltage, otherwise personal injury or damage may occur.

When connecting your devices to 

FREEDOM

, carefully consider which is the most important to have 

continued  access  to,  should  the  battery  become  flat  or  the  power  fail.  Ensure  that  this  device  is 

plugged into socket number 1. In most cases this will be device which may be used to call for attention 

so that you are able to get the unit charged, such as a warden call system.

Limiting the Number of Active Devices

Although 

FREEDOM

 is able to switch between four devices, in many cases it will be used with fewer 

than four. To avoid the need to scan to unused devices, the number of active devices may be selected 

anywhere between two and four inclusive. By default the unit is supplied to switch between all four 

devices, but if you wish to limit that number, press the Devices button [11] repeatedly until the correct 

number of LEDs [1-4] are lit*. After a few seconds of there being no further presses of the Devices 

button, the LEDs are extinguished and the settings saved.

Devices 1 and 2 are always in use and 3 and/or 4 may optionally be disabled.

*Note that the LEDs blink to help distinguish between this and normal operation.

Connecting the unit to switches

Next connect your switch to the Main Switch socket [16]. Then decide whether you wish to use this 

switch to select which device it is connected to, or whether you would like to use a second switch for 

this purpose. If you would prefer to use a second switch, plug it into the Scan Switch socket [17].

Содержание Freedom

Страница 1: ...a mobile telephone and a tablet computer Some devices for example the phone and tablet in the above example may require additional equipment to allow connectivity such as the APPlicator from Pretorian All four outputs are fully isolated so the unit can work with devices which do not share the same ground potential FREEDOM operates from a rechargeable lithium battery which is charged via the suppli...

Страница 2: ...ell time when using extended presses Powered from rechargeable battery or external power supply Fail safe connection to device 1 when the battery is flat or power fails Lock facility allows the keypad to be locked once the settings have been made Supplied with a charging cable and four device connection cables 14 15 16 17 5 6 7 8 12 9 10 1 2 4 3 11 13 ...

Страница 3: ...up to 30V and must NEVER be used to switch anything above this voltage otherwise personal injury or damage may occur When connecting your devices to FREEDOM carefully consider which is the most important to have continued access to should the battery become flat or the power fail Ensure that this device is plugged into socket number 1 In most cases this will be device which may be used to call for...

Страница 4: ...ime will result in the device seeing no press and instead the unit will scan to the next device For example if the unit is currently connected to device number 2 and there is an extended press of the main switch it will scan to device 3 Selecting the Scan Time for one Switch use Ifyouareusingasecondswitchtoscanfromdevicetodevice thereisnothingmoretodo thefirsttime you press the second switch the u...

Страница 5: ... the low battery condition even when the unit is out of sight As soon as you see or hear the low battery indicator it s time to recharge the unit via the supplied USB cable or auxiliary power supply Charging from completely flat takes around 3 hours and all the available facilities of the unit can continue to be used while charging Should the battery not be charged once it enters the low battery c...

Страница 6: ...st cases be ordered as such An alternative description is USB type A plug to mini USB plug cable Shouldyourequiremoredevicecables thesemaybeorderedfromPretorianusingthepartnumberE070010 Warranty FREEDOM is warranted against defects in manufacture or component failure for a period of 24 months The unit is designed for use in domestic and educational environments Use outside these areas will invalid...

Страница 7: ... cable or auxiliary power supply this will also charge the battery Press Power button 9 Cannot get unit to switch to sockets 3 or 4 Number of devices has been limited Use Devices button 11 to select correct number of devices Extended press of Main Switch will not scan to next available device Unit set for two switch operation Use Mode button 12 to set a Scan Time This sets the unit back to single ...

Страница 8: ... technical note about using FREEDOM with one Switch When using the main switch to scan from device to device the switch is in effect carrying out two separate functions and the unit cannot know which one the user intends when the switch is first pressed It must therefore wait until the user has released the switch to know the duration of the press and if it s a short press to be directed to the de...

Страница 9: ......

Страница 10: ......

Страница 11: ......

Страница 12: ...orianuk com Unit 37 Corringham Road Industrial Estate Gainsborough Lincolnshire DN21 1QB UK Tel 44 0 1427 678990 Fax 44 0 1427 678992 SimplyWorks is a registered trademark of Pretorian Technologies Ltd S040137 ...

Отзывы: