Pretika OxyHandSpa ST251 Скачать руководство пользователя страница 2

Congratulations and thank you for being a customer of Pretika! 

Before you start, please take a moment to get to know your OxyHandSpa and how 
it works. For important information about safety and how to use the device, read the 
full Instructions for Use booklet. Contact the experts at Pretika for any assistance in 
helping you get started.

Customer Service Contact:
1-949-481-8818
Email: [email protected]
Or visit our website at www.pretika.com
Hours of Operation:
Monday – Friday, 8:00 AM to 4:00 PM
Pacifi c Standard Time

OxyHandSpa™ Features

2

ON/OFF 

Control, 

Oxygenated 

Mist Volume 

Mode

Oxygenated 
Mist 
Temperature 
Control Mode

Easy-Fill, 
Removable 
Water Tank

Hand Treatment 
Compartment

Using OxyHandSpa™ Daily Treatment

•  OxyHandSpa  provides  the  hydrating  benefi ts  of  Oxygen–delivering  Oxygenated 
Mists to nourish dry skin. Skin care for the hands - soothing relief to dry, itchy skin and 
helps skin stay smooth and supple Use separately or in combination with moisturizers 
and skin care treatments.

Содержание OxyHandSpa ST251

Страница 1: ......

Страница 2: ...e pretka com Or visit our website at www pretika com Hours of Operation Monday Friday 8 00 AM to 4 00 PM Pacific Standard Time OxyHandSpa Features 2 ON OFF Control Oxygenated Mist Volume Mode Oxygenated Mist Temperature Control Mode Easy Fill Removable Water Tank Hand Treatment Compartment Using OxyHandSpa Daily Treatment OxyHandSpa provides the hydrating benefits of Oxygen delivering Oxygenated Mi...

Страница 3: ... Water will flow from the Water Tank into an internal reservoir Plug in the device to wall adaptor and connect DC plug into the socket on the device left rear side of device Step 2 Functional Controls On Off Oxygenated Mist Flow Control knob is located on the left side of the device turn clockwise for on position counterclockwise for off position adjust clockwise for higher oxygenated mist flow an...

Страница 4: ...back into the top cover making sure the slots match up to the grooves and press tank into place firmly OxyHandSpa is designed only for use on the counter top Keep base unit away from water and do not get wet Step 2 CONT In seconds you will see the Oxygenated Mist forming inside the Hand Treatment Compartment place both hands within compartment For larger hands treatment of one hand at a time is re...

Страница 5: ...r off 5 BE CAREFUL NOT TO HAVE DRAIN ING WATER FALL INTO CONTROLS OR VENT OPENINGS DO NOT drain in any manner other than indicated WARNING DO NOT place directly under running faucet 6 Pour about 1 cup of white vinegar into water tank and allow it to soak for only 20 to 30 minutes 7 Remove any buildup of minerals in the water tank using a small brush such as a toothbrush NOTE The buildup is due to ...

Страница 6: ...n inside wall near an electrical outlet 12 NEVER place device in an area where it is accessible to children 13 WARNING Do not attempt to refill device without first unplugging the unit from its electrical outlet Failure to heed this warning may cause per sonal injury Be sure to unplug the unit by pulling on the plug and not the cord 14 DO NOT operate any appliance with a damaged cord or plug after...

Страница 7: ...sion cord 33 Do not add any medications to the Water Tank Do not cover or insert objects into any openings on the device 34 Do not leave water in the base reser voir for long periods between use Water contains minerals and other particles During operation most of these minerals will remain in the water reservoir Gradual buildup of deposits will coat the hot water reservoir and reduce its efficienc...

Страница 8: ...sed by its negligence Pretika s entire li ability for any defective product shall not exceed the purchase price for the defective product Pretika disclaims any liability for general consequential incidental or special damages even if aware of the likelihood of such damages During Warranty Period with Proof of Purchase store receipt Should your product become defective during the warranty period pa...

Страница 9: ...oir located at base where Water Tank fits into device use Distilled or fresh tap water Oxygenated Mist Flow output is low Dirt on Atomizing Disc or too little water in Water Tank and in Reservoir Clean Atomizing element in Reservoir refill water level use Distilled or fresh tap water Abnormal Noise Low water level in Water Tank or Reservoir device not on flat surface Refill to proper level in wate...

Страница 10: ...F 91 7F 27 4 33 2º C Oxygenated Mist Duration At high Oxygenated Mist Flow setting the volume output is 150mL per hour for 100 110 minutes of continuous use At low Oxygenated Mist Flow Setting the volume output is 20mL per hour for 220 minutes of use Output Rating 24VDC 2 0A Adaptor Input 100 240Vac 47Hz 63Hz Output 24Vdc 2 0A ...

Страница 11: ...n a residential installation This equipment generates uses and can radiate radio frequency energy and if not installed and used in accordance with the instructions may cause harmful interference to radio communications However there is no guarantee that interference will not oc cur in a particular installation If this equipment does cause harmful interference to radio or television reception which...

Страница 12: ......

Отзывы: