 DIAGNOSTICS:

Enter Bank 3 and turn on selectable feature # 10 as described on the front pages of this manual.

 NOTE: 

 Diagnostic mode is a temporary mode.  Once you have accessed the diagnostic mode, the unit will 

pause for two seconds then begin to flash the last stored shut down code.  This code will be displayed three 

times in succession, then the unit will automatically exit the diagnostic on mode.

The parking lights will flash a number of times indicating the reason for the last remote start shutdown. The 

light flash indications are as follows:

1 Flash   

Run timer expired

2 Flashes 

Low or no tach signal (RPM)

3 Flashes 

Positive inhibit wire activation

4 Flashes 

NA

5 Flashes 

RF shutdown, Remote signal received, or manual start trigger wire reactivated.

6 Flashes 

High tach signal (RPM)

7 Flashes 

Tach signal has not been learned

8 Flashes 

Negative inhibit wire

 TESTING YOUR INSTALLATION:

WARNING!  

The following procedure must be performed after the installation of any Remote Start Device.  It 

is the responsibility of the installing technician to complete these tests.  Failure to test the unit in the following 

manner may result in personal injury, property damage, or both.

 HOOD PIN SAFETY SHUT DOWN:

The intent of the hood pin safety shut down is to prevent the Remote Start unit from being activated while a 

mechanic or vehicle owner is performing normal routine vehicle maintenance.  

To test the integrity of this circuit:

1. With the drivers window in the down position, start the vehicle using the RF transmitter.

2. Reach inside the car and pull the hood release.  

3.   Raise the hood and confirm that the remote start unit shuts down.  If the unit fails this test, recheck your 

pin switch connection to the Gray/Black wire of the Remote Start Unit.

  

DO NOT RELEASE THIS VEHICLE TO THE CONSUMER UNTIL YOU CONFIRM THE 

OPERATION OF THE HOOD PIN SAFETY SHUT DOWN FEATURE.

 REMOTE START OVERRIDE MODE / MANUAL SHUT DOWN:

 

The intent of the remote start override / manual shut down circuit is to allow the vehicle operator to prevent 

operation of the Remote Start Unit regardless of the RF transmitter operation.

To Enter The Remote Start Override Mode:

1)  With the system disarmed/unlocked, and the ignition switch off Press and Hold the push button switch 

located on the receiver unit on.

2) Turn the ignition switch on, off, on, off, on, off.

3)  The LED begins to flash two short flashes followed by one long flashes and continues this pattern until 

returned to normal mode of operation.

  

The action above puts the unit into the Remote Start Override mode or vehicle service mode and will not 

start from the RF transmitter or any other input.

Содержание APS-901E

Страница 1: ...age 12 13 Telematic Port Information Page 13 6 Pin Antenna Harness Page 13 Diesel Engine Settings Page 14 DBI Port Information Page 14 Engine Monitoring Selections Voltage Tach DBI Hybrid Page 14 Tach...

Страница 2: ...air bags or damage sensitive vehicle computers and electronics For technical support go to www avxtech1 com or call 1 800 225 6074 FCC COMPLIANCE This device complies with Part 15 of the FCC rules an...

Страница 3: ...bit Shutdown To Brake Switch 5 Brown Inhibit Shutdown To Brake Switch 6 Gray Inhibit Neutral Start Switch 7 Black Yellow Pulse During Crank Output 8 Black Red Pulse After Shut Down Output 9 Black Blue...

Страница 4: ...ed White Battery 1 12V 3 Green Ignition 2 4 Purple Accessory 5 Red Battery 2 12V 6 Yellow Starter Output 1 Black Chassis Ground 2 White Red Parking Light Relay Input 3 Yellow Black To Controlling Alar...

Страница 5: ...as it is not waterproof HOOD PIN SWITCH PART 1363699 The pin switch included in this package is intended for protecting the hood area of the vehicle In all cases the switch must be mounted to a ground...

Страница 6: ...nition 2 Output Connect this wire to the ignition 2 wire from the ignition switch This wire will show 12 volts when the ignition key is turned to the ON or RUN position and is some cases the START or...

Страница 7: ...gative side of the ignition coil This Remote Start unit learns the tach rate of the vehicle and in most cases will operate properly from one coil pack regardless of the number of cylinders If the unit...

Страница 8: ...hen the vehicle is in any gear other than Park or Neutral this wire can be connected to that vehicle wire to prevent starting while in gear If the vehicle you are working switches ground to the brake...

Страница 9: ...rs if the doors unlock automatically when the factory anti theft system is disarmed This wire will also activate when the transmitter is used to arm lock the system This output can be selected to oper...

Страница 10: ...irement connect terminal 30 to a fused 12 volt source or to ground and connect terminal 87 to the vehicle to supply the additional ignition source C GM VATS Key Override If the vehicle has the General...

Страница 11: ...sher relay If the vehicle you are working on has 12 volt switched parking lights connect this wire to a fused 12 volt source Max 15 Amps NOTE If the vehicle s parking lights are ground switched connec...

Страница 12: ...vides a ground pulse when the transmitter button is pressed and held for 3 seconds while running under control of the remote start Connect the Green wire to the low current ground signal wire from the...

Страница 13: ...White Data TX Yellow Data RX Connect the 4 pin harness found in the Telematic one way or Carlink II kits to the mating port on the con trolling circuit NOTE If using the TWO WAY Telematic module only...

Страница 14: ...el to go above the level it was before the vehicle began to crank which indicates the vehicle is running Feature 14 of Bank 3 must be set for averaging or the voltage sense feature will not operate in...

Страница 15: ...The intent of the hood pin safety shut down is to prevent the Remote Start unit from being activated while a mechanic or vehicle owner is performing normal routine vehicle maintenance To test the inte...

Страница 16: ...ear selector to the drive position If the unit attempts to start failing this test recheck your Yellow Wire s connection This wire must be connected to the ignition switch side of the Neutral Start Sw...

Страница 17: ...r than Park or Neutral while the key is in the ignition cylinder however if the key is left in the ignition switch and the door is left opened the added relay will be energized causing a 150mA drain o...

Страница 18: ...Striped side must be connected to the hood pin switch If the hood pin switch is also used for an alarm trigger input be certain to use the dual diode set up shown earlier in this manual AFTER THE CONN...

Страница 19: ...e to feature 2 etc then use the lock button of the transmitter to select the feature setting Example to set passive arming 1 Turn the ignition key to the on position 2 Press and release the valet prog...

Страница 20: ...ee Transmitter Programming Guide RF Programmable Features Bank 2 Is Alarm Selectable Features Feature Selection 1 Chirp 2 Chirps 3 Chirps 4 Chirps 5 Chirps 6 Chirps 1st DoorL UL 500 mS 3 5 Sec 500mS L...

Страница 21: ...s 5 Press the push button switch five times to advance to features 5 Input Check then use the lock button of the transmitter to select three chirps DBI Tach 6 To exit the programming mode turn the ign...

Страница 22: ...l 20 13th Temp Start Not Available 14th Crank Averaging Averaging Preset Time NOTE When averaging the engine must be started 4 times with the key to be effective 15th R S Shock Not Available 16th Turb...

Страница 23: ...128 9300 23 of 24 23 NOTES...

Страница 24: ...k Yellow Pulse During Crank Output Black Blue Pulse Before Start Output Black LT Green Pulse After Start Output Gray Black Inhibit Shut Down From Hood Switch Brown Black Inhibit Shut Down From Brake S...

Отзывы: