32
c.
air does not shut off
Does arc start when nozzle contacts work without depressing torch switch?
Yes
No
Check for short in torch switch
Does air flow even when Prest-O-Lite
®
550 power switch is OFF?
Yes
No
Replace
Repair/replace control
solenoid valve
PCB
B. no air
Is air hose connected?
Yes
No
Connect
Is air adjusted to 55 - 65psi (4 - 5 bar)?
Yes
No
Adjust
Does air come on with air check switch?
Yes
No
• No electrode in torch
• No valve pin in torch
• Replace electrode
Check continuity of torch switch
• Replace valve pin
OK
No
Replace torch switch
Repair /replace power source
sectioN 6
trouBleshootiNg