Oil hose end meter
Operating instructions
1.3
Technical data
Description not
calibratable
calibratable
Measuring mechanism
Oval wheels
Oval wheels
Volume flow
1 to 30 litres/min
1 to 10 litres/min
Max. operating pressure
70 bar
16 bar
Temperature range
- 10°C to + 50°C
- 10°C to + 50°C
Viscosity
8 to 5000 mPass
8 to 5000 mPass
Precision
± 0,5 %
± 0,3 %
Repeatability
± 0.3 % of the displayed
value
± 0.2 % of the displayed
value
Display LCD
LCD
Partial quantity
5-place, resettable
5-place, resettable
Total quantity
6-place, resettable
6-place, resettable only in
calibration mode
Resolution
0.002 litres
0.002 litres
Minimum dispensable
quantity
0.5 litres
0.5 litres
Unit of measure
Litres or Gallons
Litres or Gallons
Batteries
2x LR 1_1.5 Volt
2x LR 1_1.5 Volt
Connection thread
G ½"
G ½"
Table: 1-3: Technical data
2.
General safety instructions
2.1
Information on safety at work
•
The hose end meter has been designed and manufactured in compliance with the
applicable safety and health requirements of the relevant EU directives.
•
However, hazards may result from the use of this product if it is not used as
intended or with the required care.
•
When operating the hand-held volume flow meter, local safety and accident
protection regulations are always valid, as well as the safety instructions in these
operating instructions.