49
2.
Press the
CH
knob (
5
) button to
confirm
. The radio automatically
switches to
TX
mode without pressing the
PTT
switch (
12
) and
calibration begins. Calibration time is 5 minutes maximum. A
countdown is done in the display.
3.
Adjust the antenna.
- The beep* is continuous when the SWR value is
1.0
. The space
between the beeps becomes larger and larger as the SWR value
moves away from
1.0
.
- The volume of the beep is adjustable with the
VOL
button (
1
).
- The display shows the SWR value, for example
2.5
.
4.
Press the
PTT
switch (
12
) to
exit
the
SWR CALIBRATION
.
*Check that the beep volume is set to a suitable level.
See
ADJUSTMENT OF SWR
page 41.
9) ECHO ADJUSTMENT
Press the
CH
knob (
5
) for 3 seconds to
enter
MENU
. appears.
1.
Turn the rotary
CH
knob (
5
) or use the
UP/DN
buttons (
13
) on the
microphone to
select
the
ECHO SET
menu.
2.
Press the
CH
knob (
5
) button to
confirm
. The
LEVEL
of the ECHO
flashes in the display.
3.
Turn the rotary
CH
knob (
5
) or use the
UP/DN
buttons (
13
) on the
microphone to
set
the level value from
1
to
32
(default level:
13
).
4.
Press the
CH
knob (
5
) button again to
validate
the level value.
The second parameter,
DELAY
, flashes.
5.
Use the rotary
CH
knob (
5
) or the
UP/DN
buttons (
13
) on the mi-
crophone to
set
the delay value from
1
to
32
(default value:
16
).
6.
Press the
CH
knob (
5
) again to
confirm
the delay value. The delay
stops flashing.
a)
Start again at point
1
to
set
another function or
b)
Press the
PTT
switch (
12
) to
exit
MENU
.
7.
If no key is pressed, the unit
exits
MENU
after 10 seconds. dis-
appears from the display.
See §
ECHO
page 45.
10) TONE
This function allows to change the
RX
TONE
. 11 steps from
-5
to
+5
Press the
CH
knob (
5
) for 3 seconds to
enter
MENU
. appears.
1.
Turn the rotary
CH
knob (
5
) or use the
UP/DN
buttons (
13
) on the
microphone to
select
the
TONE
menu.
2.
Press the
CH
knob (
5
) to
confirm
. The tone value flashes in the
display.
3.
Turn the rotary
CH
knob (
5
) or use the
UP/DN
buttons (
13
) on the
microphone to
change
the value of the tone.
4a.
Short press the
CH
knob (
5
) again to
validate
the selected value
and
stay
in the
MENU
.
4b.
Long press (1s) the
CH
knob (
5
) again to
validate
the selected
value and
exit
in the
MENU
. disappears from the display.
5.
If no key is pressed, the unit
exits
MENU
after 10 seconds. dis-
appears from the display.
Tone default value is :
0
.
11) EMERGENCY CHANNEL 1
Press the
CH
knob (
5
) for 3 seconds to
enter
MENU
. appears.
1.
Turn the rotary
CH
knob (
5
) or use the
UP/DN
buttons (
13
) on the
microphone to
select
the
EMG 1
menu.
2.
Press the
CH
knob (
5
) button to
confirm
. The first parameter, the
modulation mode, flashes in the display.
3.
Turn the rotary
CH
knob (
5
) or use the
UP/DN
buttons (
13
) on the
microphone to
set
the modulation mode for emergency channel
1: AM, FM, USB, LSB or FM UK (in
U
configuration only).
4.
Press
CH
knob (
5
) again to
confirm
. The modulation mode stops
flashing, the second parameter, the channel, flashes in the display.
5.
Use the rotary
CH
knob (
5
) or use the
UP/DN
buttons (
13
) on the
microphone to
select
the emergency channel 1.
6.
Press
CH
knob (
5
) again to
confirm
the channel.
a)
Start again at
point
1
to
set
another function or
b)
Press the
PTT
switch (
12
) to
exit
MENU
.
7.
If no key is pressed, the unit
exits
the
MENU
after 10 seconds.
disappears from the display.
Emergency channel 1 default is
9
in AM.
See §
EMERGENCY CHANNELS
page 44.
12) EMERGENCY CHANNEL 2
Press the
CH
knob (
5
) for 3 seconds to
enter
MENU
. appears.
English