ALIGNMENT VCO/PLL
1 - Alignment procedure (13,2V/26,4V;configuration”EU”)
STEP
CONDITION
ADJUSTMENT
REMARKS OF ADJUSTMENT
1
FM(UK Eng)
RX mode
Channel 20
RT301
Connect a frequency counter to TP200,
and adjust RT301 to reach
38,48625MHz.
2
AM/FM(EU)
RX mode
Channel 20
RT302
Connect a frequency counter to TP200,
and adjust RT302 to reach
37,900MHz.
3
AM/FM(EU)
TX/RX mode
Channel 40
Connect a voltmeter to TP 302, and check:
Tx Channel 40=2,7V±0,2V
Rx Channel 40=2,6V±0,2V
4
AM/FM(EU)
TX/RX mode
Channel 1
Connect a voltmeter to TP 302, and check:
Tx Channel 1=2,5V±0,2V
Rx Channel 1=2,4V±0,2V
5
AM/FM(EU)
TX/RX mode
Channel 1 to 40
or 1 to 80(d)
Connect a frequency counter to TP200,
and check frequencies.
Содержание HENRY classic ASC 12/24
Страница 1: ...HENRY classic ASC 12 24 SERVICE MANUAL...
Страница 6: ......
Страница 14: ......
Страница 16: ......
Страница 17: ...HENRY classic ASC 12 24 BLOC DIAGRAM...
Страница 19: ...HENRY classic ASC 12 24 SCHEMATIC DIAGRAM...
Страница 20: ......
Страница 21: ...HENRY classic ASC 12 24 COMPONENT LAYOUT...
Страница 22: ......
Страница 23: ......
Страница 24: ......
Страница 25: ...HENRY classic ASC 12 24 COMPONENTS LIST...