9
the
weather
channel
blink on the display. The unit cancels
CB
or
PA
mode and goes to
WX
mode.
During a SIREN tone sound, press any key to stop the sound,
“ALERT”
and the
Weather
Channel
stop blinking on the display.
Note:
The SIREN tone sounds when an
ALERT
is detected in the
selected
weather channel only. Use first
SCAN
function in
WX
mode to detect the alerts
in
all
the weather channel
(see §
CB/
WX
page 8)
.
7) EMG ~ EMG STORE
EMG
(short press)
Emergency channels will be automatically selected by pressing
the
EMG
key (
7
). First press : emergency channel
1
is activated.
Second press: emergency channel
2
is activated. Third press: return
to the current channel.
“EMG”
appears on the display when an
emergency channel is activated. The default emergency channels
are channel
9
(
1
) and channel
19
(
2
).
Note:
Activating an emergency channel prevents use the
PA
(see
§
PA
page 11)
mode. If the
KEY BEEP
function is activated, an
error beep sounds.
EMG STORE
(long press)
Emergency channel can be stored to any channel. To set a new
emergency channel:
-
Short press the
EMG
key (
7
) to call the current emergency channel.
“EMG”
appears on the display.
- Long press the
EMG/STORE
key (
7
). appears on the display and
“EMG”
blinks.
- Using the
s
/
t
keys (
3
), select the new emergency channel.
-
Short press the
PTT
switch (
11
) to validate and store the new emer-
gency channel. A validation beep sounds.
Note:
Emergency setting is not allowed if the active channel is not
an emergency channel.
8) VOX ~ VOX SET
VOX
(short press)
The
VOX
function allows transmitting by speaking into the original
microphone (or in the optional vox microphone) without pressing
the
PTT
switch (
11
). The use of an optional vox microphone con-
nected to the rear panel of the transceiver (
E
) disables the original
microphone.
Press shortly the
VOX
key (
8
) in order to activate the
VOX
function.
«VOX»
appears on the display. A new press on the
VOX
(
8
) key
disables the function,
«VOX»
disappears.
VOX SET
(long press)
1.
Long press the
VOX/SET
key (
8
) to enter the
VOX SETTING
.
“VOX”
blinks, the current setting and its value appear on the display.
Three parameters allow to adjust the
VOX
: Sensitivity:
L
/ Anti-vox
level:
A
/ Vox delay time:
t
.
2a.
Use the
s
/
t
key (
3
) to modify the current parameter then, press
the
NB
key (
5
) to select the next parameter or....
2b.
Press first the
NB
key (
5
) to select another parameter and then use
the
s
/
t
key (
3
) to modify the current parameter.
3.
When all adjustments are done, press the
PTT
switch (
11
) to store
and exit. If the
KEY BEEP
function is activated, a long beep sounds
to confirm the success of the operation
(see §
KEY BEEP
page
10)
.
4.
If no key is pressed for 10 seconds, the unit automatically exits the
function
VOX SETTING
without saving.
-
Sensitivity
L
: allows the adjustment of the microphone (original one
or optional vox) for an optimum transmission quality. Adjustable
level from
L1
(high level) to
L9
(low level). Default value:
L5
.
-
Anti-Vox
A
: allows disabling the transmission generated by the
surrounding noise. The level is adjustable.
AF
(according the
squelch level) and from
A0
(without anti-vox) to
A9
(low level).
Default value:
AF
.
-
Delay
time
t
: allows avoiding the sudden cut of the transmission
by adding a delay at the end of speaking. The level is adjustable
from
t1
(short delay) to
t9
(long delay). Default value:
t1
.
VOX SETTING
doesn’t activate the
VOX
function.
EnglishEnglish
Содержание ANDY II FCC
Страница 1: ...Owner s manual Manual del usuario Manuel d utilisation Manual do usu rio...
Страница 53: ...53...