3        SAFETY INFORMATION FOR THE OPERATOR 

 

With the help of this Instruction Manual, instruct each user in the safe operation of this care bed before it is 
put into service for the first time.  

Advise the user of any hazards which may occur if not handled correctly.  

Only persons who have been properly instructed may operate this care bed. This also applies for persons 
who only operate the care bed on a temporary basis.  

According to section 41B of the Therapeutic Goods Act 1989, this bed is Class I medical device. 

Australian Register of Therapeutic Goods (ARTG) Number 310585 

Please observe your obligations as the operator in accordance with the Therapeutic Goods Act Products 
Ordinance, in order to ensure the permanently safe operation of this medical product with no risk of danger 
to patients, users or third parties. If the care bed is used on a long-term basis, checks for proper functioning 
and for any visible damage must be performed and documented at least once a year. 

 

 

3.1      SAFETY INFORMATION FOR THE USER 

 

Ensure the operator instructs you in the safe operation of this bed.  

In addition, pay particular attention to the general safety information as described in 

2

.  

Adjustments of the bed must only be carried out by suitably instructed persons or in the presence of an 
instructed person.  

Make  sure  the  mattress  base  is  at  its  lowest  position  before  leaving  the  patient  unattended.  This  will 
minimise the risk of injury to the patient when getting in or out of bed.  

If there is a suspected fault or damage, unplug the mains plug from the socket. Clearly mark the care bed 
as “Out of Order” and immediately take it out of service and inform the person in charge without delay. 

 

 

 

 

 

GENERAL INFORMATION   

      USER MANUAL    

 

 

 

Page 5 

      USER MANUAL    

 

 

 

Page 5 

Содержание Ultra Low Bed

Страница 1: ...READ THIS INSTRUCTION MANUAL AND OBSERVE SAFETY INSTRUCTIONS ULTRA LOW BED USER MANUAL ...

Страница 2: ...attress base control box and the motor unit must remain plugged in This is necessary to prevent water ingress to the control box Do not sit on the leg section of the bed when operating the raise function Ensure the recommended service and maintenance schedule in this manual is completed Failure to do so may invalidate warranty claims WARNINGS Before lowering the bed check the area underneath is cl...

Страница 3: ...ith the patient The care bed is not designed for the transport of patients If other electrical devices are used in the bed and to prevent the risk of an electrical shock protective measures and precautions must be established to prevent power cords being trapped in movable parts of the bed 1 2 NON COMPLIANT USE All uses deviating from the intended purpose which may also be hazardous as a result Th...

Страница 4: ...st always remain accessible to enable immediate cut off by unplugging the mains plug from the wall socket in case of emergency The mains cable must be free and away from the bed frame Otherwise the mains cable may be torn out and damaged In addition the mains plug may be pulled out of its socket and electric leads exposed as a result If the mains cable or the mains plug is damaged the relevant par...

Страница 5: ...o risk of danger to patients users or third parties If the care bed is used on a long term basis checks for proper functioning and for any visible damage must be performed and documented at least once a year 3 1 SAFETY INFORMATION FOR THE USER Ensure the operator instructs you in the safe operation of this bed In addition pay particular attention to the general safety information as described in 2...

Страница 6: ...lified A technical check and or safety inspection must be conducted at least once a year and after a lengthy break in use and before each further use See section 19 Any defects damage or signs of wear must be rectified without delay Only original spare parts from PremiumLift may be used otherwise all guarantees or warranties will be excluded The 9V block battery is the energy store for electrical ...

Страница 7: ... maneuvered in very small spaces on its castors If the bed is stored the 9V block battery should be removed When the bed is moved on the transport frame take care not to allow it to overbalance The narrow tall design saves storage space but may tip over if handled carelessly SERVICE LIFE DISPOSAL The normal service life for care beds in domestic use is approximately 5 years The care bed must not b...

Страница 8: ...7 COMPONETS LIST a HEADBOARD b FOOTBOARD c HEAD END BED PLATFORM d FOOT END BED PLATFORM e HANDSET f POWER CORD WITH PLUG g TRANSPORT KIT COMPONENTS a b c d e f g USER MANUAL Page 8 ...

Страница 9: ... transport kit To prevent fingers being trapped please hold the inside of the platform section and not on the outer frame Lay the platform section face down on the floor To remove the backrest section from the transport frame lift and slide sideways between the head and footboard sections Remove the height adjustable head and foot end panels from the transport frame by releasing the 4 lock fixings...

Страница 10: ...e other half Slide the connecting bars into the other frame Once the platform sections are together install the final fixing screws Use the supplied allen key to tighten all 8 fixings 4 fixings on each side of the platform Place head end and foot hand on the floor INSTALLATION USER MANUAL Page 10 ...

Страница 11: ... the bed chassis taking care not to damage the cables Fix the power cable to the chassis using the bracket at the head end of the bed pull the cable taut and lock the cable grip Secure the handset and power cable to the chassis using the cable clips attached to the platform Carefully turn over the sleeping platform to not damage the raise lower actuator cables Insert both platforms to lift system ...

Страница 12: ...lt remove the screw and the black cable guidance roller Insert the actuator cable and refit the roller reinstall the nut and bolt Cut the last cable ties holding the backrest and foot rest sections in place remove the final carboard protection from the head and foot sections but DO NOT cut the cable tie securing the backrest actuator Ensure the power supply is never positioned on or under the bed ...

Страница 13: ...mage the handset should always be hung by the handset hook when not in use Press only one button at a time as the system could overload and become damaged On the back of the handset there is a locking device All electric adjustment functions can be locked at the same time using the nurses key supplied OPERATION USER MANUAL Page 13 ...

Страница 14: ...e per 9V battery as the capacity of the battery is limited After the emergency lowering has been used the 9V battery must be replaced Type 6LR61 alkaline manganese battery The battery should however be replaced every 2 years even if it has not been used To replace check or remove the 9V battery before storage open the battery compartment on the power supply unit attached to the backrest motor 16 B...

Страница 15: ... Plug motor unit into mattress base motor Adjustment functions transposed Connecting cables on the connectors transposed Check plugs and connectors and change over plugging in locations No function after power failure 9V block battery is discharged Replace 9V block battery Bed only moves very slowly Bed only adjusted via the battery Mains plug not plugged in Plug in mains plug and replace the 9V b...

Страница 16: ...s any doubt about the safety or functionality of the bed or even a part of the bed as a result of the work performed below the bed should under no circumstances be in service again The service life of our care beds in domestic use is assumed to be approximately 5 years This naturally depends upon the manner of use The care bed is suitable for reuse if all above measures are taken Frequent transpor...

Страница 17: ...ol unit MC220 SMPS MC125 Voltage rating 230 240V Frequency rating 50 60 Hz Type of current AC Nominal consumption during operation 70 Watt Nominal consumption in idle state 0 5 Watt Nominal operating time Nominal idle time 2 Min 18 Min max 5 switching cycles min Primary safety fuse 2 0 A Battery for emergency lowering 9V block battery alkaline manganese 6LR61 Mattress base motor units back leg 2x ...

Страница 18: ...PURCHASE DATE DITRIBUTED BY ATTACH YOUR RECEIPT HERE PURCHASE DATE USER MANUAL Page 18 ...

Страница 19: ...NOTES USER MANUAL Page 19 PURCHASE DATE ...

Страница 20: ... com au All parts and data continually undergo further development and may therefore deviate from the details given Copyright PremiumLift Coda Furniture Holding Pty Ltd Our Full Terms Conditions are available by request or can be found on our Website PremiumLift reserves the right to alter or amend this document without notice Distributor Stamp ...

Отзывы: