premiere XH-1003 Скачать руководство пользователя страница 4

 

 

 

2.1 Safety

 

 

 
 
 
Before using the Lighted Tissue Floating Bath, please read this instruction manual 
carefully. Incorrect or inappropriate use may result in equipment damage or personal 
injury! 

 

   

This  Lighted Tissue Floating Bath is  designed for  floating paraffin sections along with 
assisting in placing the paraffin section on a slide and helping the section dry. The sole 
purpose of this Tissue Floating Bath is for histology use along with research, instruction, and 
experiments in the universities and technical secondary schools. The Tissue Floating Bath is 
not recommended for any other uses than the ones described in this manual.   

 

 
 
 
When the Lighted Tissue Floating Bath is running (unit is heating),  Please keep an area of 
about 12 inches around the Tissue Floating Bath clear while operating it. 

 

 

 
 

 

To avoid injury to personnel; do not use the following materials in the Tissue Floating Bath: 

 

 

Flammable and explosive materials 

 

Strong chemical materials  

 

Toxic or radioactive materials 

 
 
 
 
 

 

 
 

Содержание XH-1003

Страница 1: ...s to obtain the best results of this equipment Warning To prevent fire or shock hazard do not expose this unit to rain or moisture Unless labeled otherwise this equipment should be used with AC 110V 6...

Страница 2: ...1...

Страница 3: ...ble of Contents Section Table of Contents Page 1 Safety Page 2 Contents Specifications Page 3 Notes of Operation Page 4 Control Panel Setup Page 5 Operations Page 6 Trouble Shooting Page 7 8 Warranty...

Страница 4: ...ue Floating Bath is for histology use along with research instruction and experiments in the universities and technical secondary schools The Tissue Floating Bath is not recommended for any other uses...

Страница 5: ...dly contact your dealer promptly 3 2 Specifications Function Parameter Technical Data Environment of use Clean dry and flat surface Stable work surface Altitude 2000m Relative humidity 80 Temperature...

Страница 6: ...uctuate User may add as much water as needed to their comfort level avoid overfilling or risk of overflow Frequently stirring water can help keep temperatures consistent throughout water bath Use only...

Страница 7: ...ON OFF Power on off 5 2 Setup 1 Open box and remove Lighted Tissue Floating Bath from packaging 2 Place Tissue Floating Bath onto flat surface Look for visible damage to unit glass tray Contact deale...

Страница 8: ...rature to 70 C Use a laboratory thermometer not included to determine actual water temperature based on dial setting and increase or decrease as desired 2 Once the Tissue Floating Bath reaches your pr...

Страница 9: ...he internal temperature controller and raise the power of heater See following steps 1 Hold SET for five seconds to enter into parameter setting status 2 Press SET again until the screen shows then pr...

Страница 10: ...djust using or arrows Set the value to one half of previous value I Adjust this parameter should be the half value of previous step I s value 5 Continue pressing SET until the screen shows then adjust...