Installation guide and Owner’s manual

 

Page 8/10

 

20201029 

Pumping stations PSA-240/H 

 

Item # 183036 

6.2 PSA-240

 

Pumping station 

The following table specifies the cable’s recommended length (L) of the On/Off 
float for a maximum distance of 48 m (160') between the pumping station and 
the treatment system. It presents different values for 1 and 2 Ecoflo biofilters 
(or a dose of approximately 50 L and 100 L for other treatment systems). 

 

Number 
biofilter

 

(dose) 

Pipe Ø 

nominal 

Length of the pipe between the pumping station and the treatment system 

6 m (20') 

12 m (40') 

18 m (60') 

24 m (80') 

30 m (100') 

36 m (120') 

42 m (140') 

48 m (160') 

Length the On/Off float cable (presented by 'L' on the illustration above)

 

(50 L) 

25 mm (1") 

100 mm (4") 

100 mm (4") 

100 mm (4") 

125 mm (5") 

125 mm (5") 

125 mm (5") 

125 mm (5") 

150 mm (6") 

31 mm (1¼")  100 mm (4") 

100 mm (4") 

100 mm (4") 

125 mm (5") 

150 mm (6") 

175 mm (7")  200 mm (8")**  200 mm (8")** 

38 mm (1½")  100 mm

 

(4")* 

100

 

mm (4")* 

125 mm (5") 

150 mm (6") 

175 mm (7") 

200 mm (8")**  225 mm (9")**  250 mm (10")** 

50 mm (2") 

100 mm (4") 

125 mm (5") 

175 mm (7")  225 mm (9")** 

na 

na 

na 

na 

(100 L) 

25 mm (1") 

175 mm (7") 

175 mm (7")  200 mm (8")**  200 mm (8")**  200 mm (8")**  225 mm (9")**  225 mm (9")**  250 mm (10")** 

31 mm (1¼")  175 mm (7")  200 mm (8")**  200 mm (8")**  225 mm (9")**  250 mm 10")**  250 mm (10")** 

na 

na 

38 mm (1½")  175 mm (7")  200 mm (8")**  225 mm (9")**  250 mm (10")** 

na 

na 

na 

na 

50 mm (2")  200 mm (8")**  250 mm (10")** 

na 

na 

na 

na 

na 

na 

 
*The length of the cable is pre-set to that length at the plant.

 

**The alarm float has to be moved 50 mm higher than its initial position on the float tree. The length of the cable must remain at 3" (75 mm). 

 

Finally, adjust the valve so that water flows into the Ecoflo

 

biofilter at an acceptable rate and the dosage time for each hydraulic event 

(40 L, 8.8 imp. gallons, 10 US gallons) is at least 30 seconds. To check if the dosage is appropriate, the tipping bucket should fill-up a 
maximum of 12 times per hydraulic event. 
 

6.4 PSA-240H

 

Pumping station 

The following table specifies the required distance between the On/Off floats (H) according to the dosage required for the treatment 
system. 

 

Required dose 

Distance between floats (H) 

Length of the On/Off float cable 

(L) 

50 L 

17 cm 

L is pre-set at 100 mm (4") at the plant

 

100 L 

34 cm 

150 L 

51 cm 

200 L 

69 cm 

250 L 

86 cm 

 
 

7. Maintenance  

The pumping station has mechanical components, therefore, it is preferable to conduct an annual preventive inspection. Furthermore, 
it is important to comply with the regulations regarding the septic tank emptying in order to prevent large particles from escaping the 
septic tank and blocking the pump. We strongly recommend you empty your pumping station at the same time as your septic tank. 

 
 

 

 

On/Off float

 

**See note

 

Alarm

 

float

 

75 mm (3")

 

Содержание REWATEC PSA-240

Страница 1: ...OWNER S MANUAL AND INSTALLATION GUIDE Pumping stations 2020 Made in Canada...

Страница 2: ...ng station is normally used to feed low pressure distribution systems for sand filters and seepage beds when a dosing volume between 150 and 255 L is required Models PSA 240 PSA 240H Material reservoi...

Страница 3: ...coupling for water outlet pipe 50 mm 2 nominal Flexible coupling for water inlet pipe 100 mm 4 nominal 2 Dimensions description and location 2 1 Dimensions PLAN VIEW PSA 240 L H pumping station base B...

Страница 4: ...SA 240 and PSA 240H 2 3 Component location The PSA 240 and PSA 240H pumping stations must always be installed after the septic tank or after the effluent filter container if such is the case They shou...

Страница 5: ...t damaged during transportation Ensure rapid growth of vegetation to prevent soil erosion The pumping station must be accessible at all times do not cover the lid The lid must be at least 50 mm 2 abov...

Страница 6: ...lluent penetrates the biofilter Refer to the illustration PSA 240 pumping station before an Ecoflo biofilter in section 2 3 If the distance between the pumping station and the biofilter is greater tha...

Страница 7: ...n The pumping station is equipped with a high water level float connected to an alarm system This alarm system must be installed inside the residence home so it can be heard when it is activated The f...

Страница 8: ...astener that ties it to the reservoir do not leave the fastener in the pumping station and perform a visual inspection Then place the pump in the reservoir and connect the water outlet pipe using the...

Страница 9: ...m 9 250 mm 10 na na na na 50 mm 2 200 mm 8 250 mm 10 na na na na na na The length of the cable is pre set to that length at the plant The alarm float has to be moved 50 mm higher than its initial posi...

Страница 10: ...tank installer or septic tank pumper can generally take care of the situation 8 5 Odours The position of the air vent as well as other factors unrelated to the pumping station itself can prevent septi...

Страница 11: ...to access to the Pumping Station including without limiting the generality of the foregoing excavation snow removal or demolition 5 PARTICULAR EXCLUSIONS It is further expressly understood that the Cu...

Отзывы: