Owner’s manual

 

Page 6/9

 

20200908 

Ecoflo biofilter – nitrogen reduction unit (ECDn) 

 

Item # 339924 

 

What to do in case of... 

8.1 

An activated alarm  

If an alarm is activated, unrelated to a power failure, contact Premier Tech’s After-Sales Service department so the problem can be 
identified and corrected.   

8.2 

A prolonged power failure  

If a power failure that occurs during winter is prolonged, protect the components of your septic system against freezing. If you have 
any questions to restart your system, contact Premier Tech’s After-Sales Service department.  

8.3 

Flooding 

Certain sites are prone to flooding or to rises in groundwater levels. This can lead to a malfunction in your septic system or alter the 
performance of your ECDn. If this happens, contact Premier Tech's After-Sales Service department.  

8.4 

Backflow 

Backflow rarely occurs. But if it does happen, the primary tank is usually the cause. Your primary tank installer or primary tank pumper 
can generally take care of the situation. 

8.5 

Odours 

All septic systems are apt to generate gases and odours. The position of the air vent, as well as other factors unrelated to the ECDn 
itself, can prevent septic gases from dispersing properly and lead to odours. If this happens, contact Premier Tech’s After-Sales 
Service department.  

 

 
 

If you have any questions or comments,  

do not hesitate to contact Premier Tech at 1-800-632-6356. 

 

 
 
 
 
 
 
 
 
 

 

 

 

 

The information contained in this document was up-to-date and consistent with the information available at the 
time of publication. Premier Tech Ltd. makes no warranties or representations as to its accuracy. Because of its 
continuous improvement policy, Premier Tech Ltd. and its affiliated companies reserve the right to change and/or 
discontinue the manufacture of any product and/or modify technical data and prices, for any reason whatsoever 
and at its sole discretion, without further notice and without liability to anyone in this regard. ECOFLO

®

REWATEC

TM

, PREMIER TECH

®

, and PREMIER TECH & DESIGN

TM

 are trademarks of Premier Tech Ltd. or its 

affiliates. Ecoflo

®

 is protected under patents: CA2499637; US7097768; ES2285173; EP1539325 (BE, FR). Notice 

issued on 2019-01-11. For current data regarding all patent application(s) and patent(s) for this product or any 
part thereof, consult the website patentmarking.premiertech.com (reference: 3685). 

 

© 2020 Premier Tech Ltd. All rights reserved. 

Содержание ECOFLO

Страница 1: ...OWNER S MANUAL Nitrogen reduction Certified to NSF ANSI standard 40 245 2020...

Страница 2: ...reating a rapid mix of the recirculated treated effluent from the ECDn with the organic content of the raw wastewater The recirculation line between the ECDn and the primary tank is simply connected t...

Страница 3: ...ft 500 refers to the daily flow capacity 500 Capacity of 500 US gallons per day 600 Capacity of 600 US gallons per day 865 Capacity of 850 US gallons per day 1000 Capacity of 1 000 US gallons per day...

Страница 4: ...NEVER discharge content or water from a water softener or other potable water treatment devices backwash a spa or pool in your septic system NEVER discharge wastewater from a recreation vehicle campi...

Страница 5: ...ce with this Owner s Manual IMPORTANT Primary tanks can be emptied in several ways that can be classified into two categories complete emptying and selective emptying Complete emptying the most common...

Страница 6: ...ust be replaced before the system s treatment capacity and performance begins to deteriorate The filtering media is easily pumped out using a truck adapted to emptying primary tanks The new filtering...

Страница 7: ...e air vent as well as other factors unrelated to the ECDn itself can prevent septic gases from dispersing properly and lead to odours If this happens contact Premier Tech s After Sales Service departm...

Страница 8: ...ion or act of the Customer or the Customer s Successors including without limiting the generality of the foregoing refusal to allow access to the system for maintenance i Any damage or problem if it i...

Страница 9: ...ll be interpreted according to and governed by the provisions of this Warranty and the legislation in effect in the Province of Quebec 11 PRIORITY OF THE CERTIFICATE OF WARRANTY This Warranty supersed...

Страница 10: ...______ I hereby declare that the residence serviced by a Premier Tech treatment system located at the above address changed ownership on this date If you are the PREVIOUS owner I have provided the sys...

Отзывы: