Step 4
Installing the Wall Plate (cont’d)
Place the wall plate against the wall over the threaded
shafts of the concrete wedge anchors.
Attach the nuts and washers to each of the concrete
wedge anchors and tighten using a socket wrench
and ½
″
socket.
Do not overtighten the wedge anchor nuts.
Proceed to the
“Mounting Hardware”
section.
Mounting Hardware
Selecting the Mounting Hardware
Insert the Thread Depth Indicator into the thread
inserts found on the bottom or top of the
fl
at panel.
Use a pencil to mark the depth of the thread insert on
the Thread Depth Indicator, as shown in Figure 1.
Insert the Thread Depth Indicator into the remaining
thread inserts to compare and verify their depth.
Locate the correct diameter screw for the thread
insert.
If the screw you selected is longer than the mark on
the Thread Depth Indicator, as shown in Figure 2 and
Figure 3, do not use this screw. The screw length
must not bypass the mark.
Test each size of the screws provided.
The correct screws should thread easily into the
mounting point and not pull out when tension is
applied.
Does your
fl
at panel have:
●
Recessed mounting points?
●
Uneven mounting points?
●
A curved back?
●
Any obstruction near the mounting point?
If
Yes
, you must install Universal Spacers. Proceed to
the
“Universal Spacer Installation”
section.
If
No
, skip to the
“UFP-280 Adapter Plate Installation”
section.