PRF
Page 8
Installation Instructions
Installing the PRF-280 Mount (cont’d)
All electrical wiring should be done prior to mount
installation. You may use the optional two (2)
6-32x1” Phillips head screws to secure a standard
electrical handibox to the mount.
Step 3
Re-level the wall plate before securing to the wall.
Place the wall plate over the plastic wall anchors,
aligning the mounting holes.
Secure the wall plate using four (4) #10 x 1-
1
/
4
˝ mounting
screws.
Use a screwdriver to tighten the #10 x 1-
1
/
4
˝ screws.
Step 4
˝
Step 2
Solid Surface
1
/
16
˝
Drill Bit
Mounting Hole
Power Drill
Drill four (4) holes using a
1
/
16
˝
drill bit and power drill.
Insert four (4) #10 plastic wall anchors into the holes that
were drilled.
Use a hammer to gently tap the plastic wall anchors into
place.
#10 Plastic
Wall Anchor
Hammer
Do not over-tighten the mounting screws.
Solid Surface
Level
Wall Plate
#10 x 1-
1
/
4
˝
Screw