background image

 

PAT TESTING 

When used in a workplace, this product should be safety-tested yearly by a qualified 
electrician (PAT tested). We recommend that it is PAT tested regularly when used 
in a domestic environment. 
 

GENERAL SAFETY REQUIREMENTS 

Domestic wiring must be tested periodically by a qualified electrician at least once 
every 10 years, or at every change of occupancy. For office and retail premises, 
and buildings such as village halls, the wiring must be inspected at least once every 
5  years.  It  is  recommended  that  all  buildings  be  fitted  with  smoke  alarms  (it  is 
mandatory for new buildings). 
 

OPERATING COSTS 

At time of going to press, the average cost of electricity is £0.145 per unit (kilowatt-
hour). The amount you are being charged will be shown on your electricity bill. At 
this cost, the EH1896 will cost £0.29 per hour to run, with the heater on full power 
and  thermostat  set  to  maximum.  If  the  thermostat  is  used  to  regulate  the 
temperature, the operating costs will be lower, depending on the room temperature 
and the size of the room. 
 

MAINTENANCE 

Before  cleaning,  turn  the  heater  off  and  disconnect  from  the  mains  supply.  the 
heater may then be cleaned using a damp cloth with a drop of washing-up liquid to 
remove any dust or dirt from the case. Do not use stronger detergents or solvents 
as these may damage the case. Using a dry 1” (25mm) paint brush, remove any 
dust  from  the  grilles.  If  the  mains  lead  is  damaged,  it  must  be  replaced  by  the 
manufacturer  or  an  authorised  service  centre.  If  the  mains  plug  needs  to  be 
replaced, proceed as follows:  
 
Connect the brown (live) wire to the terminal “L” 
Connect the blue (neutral) wire to the terminal “N” 
Connect the yellow and green (earth) wire to the terminal “E” 
 
Ensure the cord grip is positioned correctly (over the outer sheath of the cable) and 
is fully tightened.

  

13A

 

Содержание EH1896

Страница 1: ...1 EH1896 2kW Overdoor Heater ...

Страница 2: ...st be installed at least 1 8m above the floor Children shall not play with the appliance Cleaning and user maintenance shall not be made by children without supervision Do not cover the heater For indoor use only Do not use in bathrooms Do not use in wet or damp locations Do not place the mains lead beneath a carpet or rug Do not position heater immediately below a socket outlet Before using pleas...

Страница 3: ...be positioned at a distance of 385mm apart and at least 1 87m from the floor the base of the unit must be at least 1 8m from the floor Secondary fixing point hole must be located centrally and below the unit to align with the secondary fixing point bracket The unit will need to be hung on the primary fixing points first then mechanically fixed through the secondary fixing point The unit must not b...

Страница 4: ...will disappear when the heater has been on a short while If the smell does not disappear we advise to switch off the heater and contact a specialist 1 ON OFF Main power button 2 24H Setting timer from 1 24 hours 3 MODE COLD WARM HOT 3 setting for selection 4 LOCK Child Lock function for heater 5 AUTO Window Open Function 6 Delay Set the open and closed time of heater 7 W Timer Set the timer of one...

Страница 5: ...ct time until the power is disconnected Remote Control Operation Turn on the machine by pressing the ON OFF button The fan function will operate and blow cool air the FAN M light will illuminate To set to heating mode press MODE button once the unit will operate at half heating power and the I W light will illuminate Press MODE button again to set the unit to full heating power the II H light will...

Страница 6: ... the Switch ON and Switch OFF times the heater will operate The following steps 1 5 must be completed together to set an operating window To set the ON time 1 SET DAY press once I W and W TIMER light will illuminate use to choose the day to program 2 SET HOUR Press again II H light will illuminate Use to set the start hour 3 SET MINUTE Press again FAN M light will illuminate use to set the start m...

Страница 7: ...programmed from the remote During normal operation select to enable the function the AUTO light will be illuminated Press again to disable the function and the AUTO light will go out Child Lock Function This function can only be programmed through the remote control Press the button once All the LED lights will go out and only the power light will remain illuminated In this mode both the control p...

Страница 8: ...ost 0 29 per hour to run with the heater on full power and thermostat set to maximum If the thermostat is used to regulate the temperature the operating costs will be lower depending on the room temperature and the size of the room MAINTENANCE Before cleaning turn the heater off and disconnect from the mains supply the heater may then be cleaned using a damp cloth with a drop of washing up liquid ...

Страница 9: ...TY Prem I Air guarantees the product free from defects in materials and workmanship for a period of 1 year Should this unit be operated under conditions other than those recommended at voltages other than the voltage indicated on the unit or any attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations T...

Отзывы: