FAULT FINDING

If the overload trip on the transformer operates, check that
the transformer has a CONTINUOUS rating of at least 2000
Watts.

DISPOSAL AND RECYCLING

You must not dispose of this appliance with domestic
household waste. 

Most local authorities have specific collection system for
appliances and disposal is free of charge to the end-user.
When replacing an existing appliance with a similar new
appliance your retailer may take the old appliance for
disposal.

TECHNICAL SPECIFICATION

Dimensions:

880x490x550mm

Weight:

15.7kg

Power supply:

110V AC

Power consumption:

2000W

Operating current:

18A

Connector

32A 110V plug

 Page 6

Содержание EH0209

Страница 1: ...9 JDO110V Heavy Duty 110V Halogen Heater 2 Heat settings Adjustable thermostat Free standing or wall mounting Convenient carrying handle Safety overload cut out Operates from site safety transformers Page 1 ...

Страница 2: ...th castors to the underside of the heater using the M6x45mm screws provided The braked castors should both be at the back of the heater Return the heater to the upright position Attach the handle to the sides of the main body of the heater using the M6x45mm screws provided ensuring that the handle is to the back of the heater PRODUCT SAFETY This appliance is not intended for use by persons includi...

Страница 3: ...o not use the heater in locations where paint petrol or other flammable liquids are used or stored Do no insert any object into the heater through the grilles This may damage the heater or result in overheating or electric shock Do not use this heater with a programmer timer separate remote control or any other device that switches the heater on automatically since a fire risk exists if the heater...

Страница 4: ...oth braked castors Use the two switches on the side to select the required operation One switch on Low Heat 1000W Both switches on High Heat 2000W Do not touch the air output grille when the heater is in operation because it will be hot and may cause burns Unplug the heater from the mains when not in use OPERATING COSTS At time of going to press the average cost of electricity is 0 11 per unit kil...

Страница 5: ...e Connect the blue wire to the terminal labelled N or unlabelled Connect the green yellow wire to the terminal labelled with the earth symbol or E Make sure that the cord grip is positioned correctly over the outer sheath of the cable and it fully tightened REPLACING THE TUBE Disconnect from the mains supply and wait until the heater has cooled down Using a pozidriv screwdriver remove the grille P...

Страница 6: ... household waste Most local authorities have specific collection system for appliances and disposal is free of charge to the end user When replacing an existing appliance with a similar new appliance your retailer may take the old appliance for disposal TECHNICAL SPECIFICATION Dimensions 880x490x550mm Weight 15 7kg Power supply 110V AC Power consumption 2000W Operating current 18A Connector 32A 11...

Страница 7: ...ed on the unit or any attempts made to service or modify the unit then the warranty will be rendered void The product you buy may sometimes differ slightly from illustrations This warranty is in addition to and does not affect your statutory rights If you have any problems with this product please call our Help Desk on 0845 459 4816 Prem i Air Appliances Ltd Lancots Lane Sutton Oak St Helens Merse...

Отзывы: