AFV-P Series High Performance Programmable AC Power Supply
86
reactive power less than 1VAR, the output of the maximum rated reactive
power will be disabled, and this icon status will be OFF.
13)
: Press to set the minimum output reactive power
for the desired Step, with options which are similar to that of the maximum
output reactive power.
14)
: Press to set the maximum output crest factor for
the desired Step, with options from 0.01 to 10. While setting the maximum
output crest factor less than 0.01, the output test of the maximum output
crest factor will be disabled, and this icon status will be OFF.
15)
: Press to set the minimum output crest factor for
the desired Step, with options which are similar to that of the maximum
output crest factor.
16)
: Press to move to the previous page of the LIMITS subpage.
17)
: Press to move to the next page of LIMITS subpage.
NOTICE
The LIMITS feature can be performed with the STEP feature simultaneously, so as
to perform the output test for the STEP feature. However, when either the RAMP
feature or the TRANSIENT feature is enabled, the LIMITS feature will not be disa-
bled.